Haier AS53TCCHRA-SET Tempo 5.0KW Hi Wall Split System Air Conditioner

OPERATION MANUAL

For AS53TCCHRA-SET. Additionally, the document applies to other Haier models: AS09TACHRA, AS12TBCHRA, AS18TCCHRA, AS24TECHRA, AS26TACHRA, AS35TBCHRA, AS53TCCHRA, AS71TECHRA

PDF File Manual, 8 pages, Read Online | Download pdf file

background
Please read this operation manual before using the air conditioner.
Keep this operation manual for future reference.
SPLIT TYPE ROOM AIR CONDITIONER
OPERATION MANUAL
0011511007
7
1
2
6
5
Contents
PARTS AND FUNCTIONS
OPERATION
MAINTENANCE
CAUTIONS
TROUBLE SHOOTING
AS09TACHRA
AS12TBCHRA
AS18TCCHRA
AS24TECHRA
AS26TACHRA
AS35TBCHRA
AS53TCCHRA
AS71TECHRA
条形码绘制区
Loading page 2...
Loading page 3...
Loading page 4...
Loading page 5...
Loading page 6...
Loading page 7...
Loading page 8...

Other documents for Haier AS53TCCHRA-SET

The following documents are available:
User Manual Specification
  • AS53TCCHRA-SET - Haier - Specifications Sheet - (English) Download
Photos

Specifications

OPERATION MANUAL - Transcript

  • Page 1 - English - : Please read this operation manual before using the air conditioner Keep this operation manual for future reference SPLIT TYPE ROOM AIR CONDITIONER OPERATION MANUAL Contents PARTS AND FUNCTIONS OPERATION MAINTENANCE CAUTIONS TROUBLE SHOOTING AS09TACHRA AS12TBCHRA AS18TCCHRA AS24TECHRA AS26TACHRA AS35TBCHRA AS53TCCHRA AS71TECHRA 条形码绘制区
  • Page 2 - English - : Outdoor Unit OUTLET INLET CONNECTING PIPING AND ELECTRICAL WIRING DRAIN HOSE Loading of the battery Remove the battery cover Load the batteries as illustrated 2 R03 batteries resetting key cylinder Be sure that the loading is in line with th equot quotquotquot Load the batterythen put on the cover again The distance between the signal transmission head and the rece iver hole should be within 7m without any obstacle as well When electronicstarted type fluorescent lamp or change over wireless telephone is installed in the ver is apt to be disturbed in receiving the signals so the distance to the indoor unit should be shorter type fluorescent lamp or room the recei Note Full display or unclear display during operation indicates the ries have been used up Please change batteries If the remote controller cant run normally during operation please reload several minutes later batte remove the batteries and Parts and Functions Remote controller If the unit which you purchased has healthy functionfollow itIf notplease ignore NOTE Cooling only unit do not have displays and functions related with heating Indoor Unit 1 Mode display 2 Signal sending display 4 FAN SPEED display 5 LOCK display 6 TIMER OFF display TIMER ON display 7 TEMP display Used to lock buttons and LCD display 25 RESET button When the remote controller appears abnormal use a sharp pointed article to press this button to reset 22 HOUR button Control the lightening and extinguishing of the indoor LED display board 9 QUIET button 10 HEAT button 11 COOL button 12 AUTO button 13 FAN SPEED button 14 TIMER button 15 SELF CLEAN button 16 LOCK button 17 LIGHT button 18 POWER ONOFF button 19 DRY button 20 TEMP button 21 SWING button 23 EXTRA FUNCTION button 24CANCELCONFIRM button Function Setting and cancel to the timer and other additional functions 3 SWING display Operation mode AUTO FAN COOL DRY Remote controller HEAT LO MED HI AUTO Display circulated the remote Additional functions display Operation mode Remote controller QUIET TURBO SLEEP Function Sleeping Healthy airflow position1 Healthy airflow position 2 Power sending AB yard Actual inlet grille may vary from the one shown in the manual according to the product purchased Display board adjust left and ow Vertical blade r ight air fl Air Purifying Filter Inlet inside Emergency Switch Horizontal flap adjust up and down air flow Dont adjust it manually Outlet Inlet grille inside Anion generator Display board Operation mode indicator lights up when the compressor is on Timer mode indicator Lights up whenTimer operation is selected Power indicator Lights up when unit starts Remote signal receiver A beeping sound is generated when a signal from remote controller isreceived HEALTH Air HEALTH
  • Page 3 - English - : Operation Unit start stop In HEAT modewarm air will blow out after a short periodof the time due to colddraft prevention function When FAN is set to AUTO the air conditioner automatically adjusts the fan speed according to room temperature Cooling only unit do not have displays and functions related with heating Display Board Remote Controller Note COOL DRY HEAT FAN nothing In DRY mode when room temperature becomes lower than tempsetting2 o Cunit will run intermittently at LOW speed regardless of FAN setting Under the mode of auto operation air conditioner will automatically select Cool or Heat operation according to room temperature air conditioner automatically adjusts the fan speed temperature When FAN is set to AUTO the according to room In FAN operation mode the unit will not operate in COOL or HEAT mode but only in FAN mode AUTO is not available in FAN modeAnd tempsetting is disabled In FAN modeSLEEP operation is not available Operation Mode AUTO Press FAN button For each press fan speed Remote controller Press button Every time the button is pressed tempsetting increase 1 o Cif kept depressed it will increase rapidly Every time the button is pressed tempsetting decrease 1 o Cif kept depressed it will decrease rapidly Select a desired temperature 3Fan speed selection 2Select tempsetting Air conditioner is running under displayed fan speed When FAN is set to AUTO the air conditioner automatically adjusts the fan speed according to room temperature 1 Unit start Press ONOFF on the remote controller unit starts Remote controller changes as follows at air outlet if all vertical louvers are right mode controller will automatically Note set swing position Remote controller Air Flow Direction Adjustment Press button again vertical flap will stop over present position the swing function will be cancelled 2Press button changes as follows Pos4 1Vertical flap Pos1 Pos2 Pos3 3Press button to choose the Pos2 and Pos3 Pos4 Pos5 Autoswing COOLDRYAUTOInitial state HEATInitial state no LOW MED HI AUTO Display circulated When restart after remote turning off the remote return to the previous Cautions When adjusting the flap by handturn off the unit When humidity is highcondensate water might occur adjusted to left or It is advisable not to keep horizontal flap at downward position for a long time in COOLor DRY otherwise condensate water might occur DRED Operation Haier Peaksmart enabled airconditioners have a Demand Response Mode display on the indoor unit The display could be labelled d1 d2 d3 wording may differ model to model odottahWnoitpircseDyalpsiDedoM DRM3 d3 Your airconditioner will continue to cool or heat during the peak demand event The energy consumed by your airconditioner is capped to 75 No action is required DRM2 d2 Your airconditioner will continue to cool or heat during the peak demand event The energy consumed by your airconditioner is capped to 50 No action is required DRM1 d1 Your airconditioner is still turned on and the fan will continue to operate Your compressor is turned off and coolhot air will no longer be generated DRM1 mode is only activated during emergency demand management situations This mode will automatically reset the device within 2 hours If your aircon is in this mode for longer than 2 hours please contact Energex on 13 12 53 This function is unavailable on some models These modes are described in more detail below
  • Page 4 - English - : Operation POWERSOFT Operation Emergency Operation 16 do not use it in the normal operation Test operation Use this switch in the test operation when the room temperature is below Continue to press the test operation switch for more than 5 seconds After you hear the Pi sound twice release your finger from the switch the cooling operation starts with the air flow speed Hi Test operation switch is the same as emergency switch Emergency operation and test operation Use this operation only when the remote controller is defective or lost When the emergency operation switch is pressedthequot Pi quotsound is heard once which means the start of this operation In this operation the system automatically selects the operation modescooling or fan or heataccording to the room temperature It is not possible to operate in dry mode Room temperature Operation mode Designated temperature Timer mode Air flow ABOVE 23 O C BELOW 23 O C COOLING HEAT O C O C NO NO AUTOMATIC AUTOMATIC Pi Cooling only uint Room temperature Operation mode Designated temperature Timer mode Air flow BELOW 23 O C FAN O C NO AUTOMATIC Pi Pi After 30 minutes test operation ends automatically This function is unavailable on some models 1 POWER Operation 2 QUIET Operation Note When you need rapid heating or cooling you can use this function You can use this function when silence is needed for rest or reading During POWER operation in rapid COOL mode the room will show inhomogeneous temperature distribution Long period QUIET operation will cause effect of not too cool or not too warm Press QUIET button the remote controller will show and then achieve to the quiet function Press again this QUIET button the quiet function will be cancelled Press button to enter additional options when cycle display to will flashand then press enter to power function When cancel the function please enter additional options again and to cancel power function 1After unit starts select your desired operation mode 2Press TIMER button to change TIMER mode Every time the button is pressed display changes as follows Remote controller Then select your desired TIMER mode TIMER ON or TIMER OFF or TIMER ONOFF quot quotor quot quotwill flash Timer OnOff OnOff Operation BLANK TIMER ON TIMER OFF TIMER ONOFF 3Press button to set time It can be adjusted within 24 hours Hints After replacing batteries or a power failure happens time setting should be reset According to the Time setting sequence of TIMER ON or TIMER OFF either StartStop or StopStart can be achieved TIMER OFFON 05h 05h 05h 05h Press the button for each time setting time in the first 12 hours increased by 05 hour every time after 12 hoursincreased by 1 hour every time Press the button for each time settiing time in the first 12 hours decreased by 05 hour every time after 12 hoursdecreased by 1 hour every time After adjust the timepress button and confirm the time ON or OFF button will not flash any more 4Confirm timer setting 5Cancel timer setting Press the button by times until the time display eliminated Self Clean Operation Functional description the purpose of this function is to clean the evaporator Entry and exit Press self clean button to enter this function then it will display quotCLquot on the panel of the indoor unit and also on the remote controller After running 2030 minutes this function will exit automatically when the quot Pi quot sound is heard twice then the unit returns to original state Under operation process of self clean pressing the button repeatedly has no effect and the function will not exit but pressing the power off button and other mode button can make it exit
  • Page 5 - English - : Comfortable SLEEP Operation 3In AUTO mode corresponding sleep mode adapted to the automatically selected operation mode 4 In FAN mode It has no SLEEP function 5 When comfortable sleeping function is set to 8 hours the comfortable sleeping time can not be adjustedWhen TIMER 2In HEAT mode 1 hour after SLEEP mode starts temp will become 2 C lower than temp setting After another 1 hour temp decrease by 2 C further After more another 3 hours temp rises by 1 C furtherThe unit will run for further 3 hours then stopsTemp is lower than temp setting so that room temperature wont be too high for your sleep O O SLEEP operation starts SLEEP operation stops 1 hr 1 hr 3 hrs 3 hrs Rises 1 O C Tempsetting Unit stop In HEAT mode Decreases 2 O C Decreases 2 O C The unit operates in corresponding sleep mode Operation Mode 1 In COOLDRY mode SLEEP operation starts SLEEP operation stops Approx6hrs 1 hr Rises 1 O C Rises 1 O C Tempsetting Unit stop In COOL DRY mode 1 hr 1 hour after SLEEP mode startstemp will become higher than temp setting After another 1 hour temp risesby 1 futher The unit will run for further 6 hours then stops Temp is higher than temp setting so that room temperature wont be too low for your sleep O C O C Press button to enter additional options when cycle display to will flash And then press enter to sleep function O function is setthe comfortable sleeping function cant be set up After the sleeping function is set upif user resets TIMER function the sleeping function will be cancelled the machine will be in the state of timingonif the two modes are set up at the same time either of their operation time is ended first the unit will stop automaticallyand the other mode will be cancelled Note When TIMER function is set the sleeping function cant be set up After the sleeping function is set upif user resets TIMER function the sleeping function will be cancelled the machine will be in the state of timingon Power Failure Resume Function If the unit is started for the first time the compressor will not start running unless 3 minutes have elapsed When the power resumes after power failure the unit will run automatically and 3 minutes later the compressor starts running Healthy airflow Operation 1Press to starting Setting the comfort work conditions 2The setting of healthy airflow function Note 1After setting the healthy airflow function the position grill is fixed 3In cooling and dry using the air conditioner for a long time under the high air humidity condensate water may occur at the grille Notice Do not direct the flap by hand Otherwise the grille will run incorrectly If the grille is not run correctly stop for a minute and then start adjusting by remote controller 2In cooling it is better to select the mode 3The cancel of the healthy airflow function Press button to enter additional optionsPress this button continuously the louvers location will cycle between in the following three locations to choose the swing location what you neededand then press button to confirm Press button to enter additional optionsPress this button continuously the louvers location will cycle between in the following three locations againand then press button to cancel Healthy airflow upwarder Healthy airflow downwarder Present position
  • Page 6 - English - : Maintenance For Smart Use of The Air Conditioner Setting of proper room temperature Close doors and windows during operation If the unit is not to be used for a long time turn off the power supply main switch Use the timer effectively Use the louvers effectively Do not block the air inlet or outlet Proper temperature During cooling operation prevent the penetration of direct sunlight with curtain or blind OFF Air Filter cleaning Open the inlet grille by pulling it upward Remove the filter Clean the filter Attach the filter Close the inlet grille Push up the filters center tab slightly until it is released from the stopper and remove the filter downward Use a vacuum cleaner to remove dust or wash the filter with waterAfter washing dry the filter completely in the shade Attach the filter correctly so that the quotFRONTquot indication is facing to the frontMake sure that the filter is completely fixed behind the stopperIf the right and left filters are not attached correctly that may cause defects Remote Controller Do not use the following for cleaning Do not use water wipe the controller with a dry clothDo not use glass cleaner or chemical cloth Gasolinebenzine thinner or cleanser may damage the coating of the unit Hot water over 40 O C104 O F may cause discoloring or deformation Wipe the air conditioner by using a soft and dry clothFor serious stainsuse a neutral detergent diluted with waterWring the water out of the cloth before wipingthen wipe off the detergent completely Indoor Body Once every two weeks 1Open the lnlet Grille 2Detach the standard air filter 3Attach Air Purifying Filter 4Attach the standard air filter Necessary installation 5Close the Inlet Grille Close the Grille surely Slide the knob slightly upward to release the filter then withdraw it Put air purifying filter appliances into the right and left filter frames Detach old Air Purifying Filter NOTE The photocatalyst air purifying filter will be solarized in fixed time In normal family it will be solarized every 6 months Prop up the inlet grille by using a small device named grillesupport ATTENTION The white side of the photocatalyst air purifying filter face outside and the black side face the unit The green side of the bacteriakilling medium air and the white side face the unit Please keep the bacteriakilling medium air purifying filter in avoid long time directly sunshine when you stop using itor its ability of sterilization will be reduced The bacteriakilling medium air purifying filter will be used for a long timeno need for replacement But in the period of using them you should remove the dust frequently by Replacement of Air Purifying Filter which located in the right side of the indoor unit purifying filter face outside using vacuum cleaner or flaping them lightlyotherwise its performance will be affected the cool and dry conditions NOTE Air purifying filter is optional part
  • Page 7 - English - : Cautions WARNING Please call SalesService Shop for the Installation Do not attempt to install the air conditioner by yourself because improper works may cause electric shock fire water leakage Connect the earth cable earthing WARNING When abnormality such as burntsmall found immediately stop the operation button and contact sales shop OFF Use an exclusive power source with a circuit breaker ENFORCEMENT Connect power supply cord to the outlet completely Use the proper voltage Do not use power supply cord in a bundle Take care not to damage the power supply cord 1Do not use power supply cord extended or connected in halfway STRICT ENFORCEMENT STRICT STRICT ENFORCEMENT PROHIBITION PROHIBITION PROHIBITION PROHIBITION Do not start or stop the operation by disconnecting Do not channel the air flow directly at people especially at infants or the aged Do not try to repair or reconstruct by yourself Do not use for the purpose of storage of food art work precise equipment breeding or cultivation CAUTION Take fresh air occasionally especially when gas appliance is running at the same time PROHIBITION STRICT ENFORCEMENT Do not operate the switch with wet hand PROHIBITION PROHIBITION PROHIBITION PROHIBITION PROHIBITION Do not install the unit near a fireplace or other heating apparatus Check good condition of the installation stand Do not pour water onto the unit for cleaning PROHIBITION Do not place animals or plants in the direct path of the air flow Do not place any objects on or climb on the unit Do not place flower vase or water containers on the top of the unit Do not insert objects into the air inlet or outlet PROHIBITION PROHIBITION PROHIBITION STRICT ENFORCEMENT Check proper installation of the drainage securely the power supply cord and so on Do not install in the place where there is any possibility of inflammable gas leakage around the unit 3Do not get the unit exposed to vapor or oil steam
  • Page 8 - English - : 3 If the fuse of indoor unit on PC board is it with the type of T 315A 250V outdoor brokenchange it with the type of T25A250V The refrigerating circuit is leakproof 1Applicable ambient temperature range Specifications The machine is adaptive in following situation The power plug and connecting cable acquired the local 2 If the power supply cord is damaged it must be replaced manufacturer qualified person 4 The wiring method should be in line with the local wiring 5 After installation the power plug should be easily reached 6 The waste battery should be disposed properly 7 The appliance is not intended for use persons without supervision 8Young children should be supervised with the appliance 9 Please employ the proper power plug cord 11In order to protect the unitsplease turn 30 seconds later cutting off the power Cooling Indoor MaximumDBWB MaximumDBWB DB MaximumDB DB MinimumDBWB MaximumDBWB MinimumDB Outdoor Indoor Outdoor Heating o C23 o C o C18 o C o C o C26 o C o C o C o C15 o C Outdoor MaximumDBWB MinimumDB o C18 o C o C INVERTER o C Minimum Minimum or its service agent or a similar brokenplease If the fuse of standard by young children or to ensure that th ey which fit into the must have off the AC first by the change unit is infirm do not play p ower supply attestation and at least Do not obstruct or cover the ventilation conditonerDo not put fingers inletoutlet and swing louver This appliance is not intended for use by persons including children with reduced physiced sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of appliance by person responsible for their safety Children should be supervised to ensure that they do not play with the appliance grille of the air or any other things into the Trouble shooting Normal Performance inspection Noise is heard Phenomenon Cause or check points The system immediately Smells are generated Mist or steam are Multiple check Poor cooling When unit is stopped it wont restart elapsed to protect the system When the electric plug is pulled out and reinserted the protection circuit During unit operation or at stop a swishing or gurgling noise may This noise is generated by refrigerant flowing in the system During unit operation a cracking noise may be heardThis noise is temperature changes Should there be a big noise from filter may be too dirty This is because the system circulates smells from the interior During COOL or DRY operation This is due to the sudden cooling Is power plug inserted Is there a power failure Is fuse blownout Is the air filter dirty Are there any obstacles before Is temperature set correctly Are there some doors or Is there any direct sunlight through the window during the Are there too much heat sources or too many people in the room In dry mode fan speed cant be changed In DRY mode when room temperature setting2 o Cunit will run regardless of FAN setting during cooling operation cooling operationUse curtain windows left open inlet and outlet Normally it should be cleaned every 15 days intermittently at LOW speed becomes lower than temp indoor unit may blow out mist of indoor air air such as the smell of furniture paint cigarettes air flow in unit operation air generated by the casing expanding or shrinking because of be heardAt first 23 minutes after unit start this noise is more noticeable will work for 3 minutes to protect the air conditioner immediately until 3 minutes have Cautions Before asking for service check the following first blown out does not restart