Troubleshooting
Problem
Engineis running, hut no AC
output is available.
Engineruns good at no-load
but"hogs down"when loads
are connected.
Cause
1. Oneof the circuit breakers is open.
2. Fault in generator.
3. Poor connection or defective cord set.
4. Connected device is bad.
.
2.
3.
4.
5.
1.
Short circuit in a connected load. 1.
Enginespeed is too slow. 2.
Generator is overloaded. 3.
Shorted generator circuit. 4.
Clogged or dirty fuel filter. 5.
Engine rocker switch set to "Off" 1.
Correction
1. Reset circuit breaker.
2. Contactauthorized service facility.
3. Checkand repair.
4. Connectanother device that is in good
condition.
Disconnect shorted electrical load.
Contactauthorized service facility.
SeeDon't OverloadGenerator.
Contactauthorized service facility.
Cleanor replace fuel filter.
Set engine rocker switch to
Enginewill not start; or starts
position.
2. Fuel Valve is in "Off" position.
3. Low oil level.
4. Dirty air cleaner.
5. Clogged or dirty
6. Out of fuel.
7. Stale fuel.
.
3.
"On'position.
Turn fuel valve to "On" position.
Fill crankcase to proper level or place
level surface.
replace air cleaner.
or dirty fuel filter.
tank.
fuel tank and carburetor; fifl with
fresh fuel.
Engineshutsdown when
running.
Enginelackspower.
Engine"hunts" or falters.
11. Flooded.
12. Excessive;l_ic_ _8_imixture.
13. IDt_vaJ _ S_ ck _pen or closed.
14. _ngifi_ h_s lost compression.
1. Out_ fuel.
2. Clogged or dirty fuel filter.
1. Load is too high.
2. Dirty air filter.
3. Clogged or dirty fuel filter.
1. Carburetoris running too rich or too lean.
2. Clogged or dirty fuel filter.
Connectwire to spark plug.
Replacespark plug.
Drain gas tank and carburetor; fill with
fresh fuel.
11. Wait 5 minutes and re-crank engine.
12. Contact authorized service facility.
13. Contact authorized service facility.
14. Contact authorized service facility.
1. Fill fuel tank.
2. Cleanor replace fuel filter.
1. SeeDon't OverloadGenerator.
2. Replaceair filter.
3. Cleanor replace fuel filter.
1. Contactauthorized service facility.
2. Cleanor replace fuel filter.