4. Drill a 1/8” dia. pilot hole for house wiring,
at A location on template.
5. Use a sharp pencil or 1/8” drill bit to mark the
locations for the appropriate duct access holes
(16 locations for 7” round duct, or 4 corner locations
for rectangular duct). Remove the template.
FRAMED CABINET
7/64”
XY
Z
Refer to the marking on the brackets to determine
the correct installation side and orientation.
Mate the corresponding bracket to the cabinet
side frame, while placing rear end of bracket
against the wall. Use a pencil to mark 3 holes
(there are 6 holes but only 3 are necessary).
Remove the bracket. Using a 7/64” drill bit,
drill 3 holes where marked.
7. Install the proper installation brackets according to
the type of cabinet (framed or frameless). See below.
6. Draw the border for the exhaust ducting by linking its
marks (16 for round duct and 4 for rectangular duct),
then cut the opening in the cabinet bottom (vertical
exhaust) or in the wall (horizontal exhaust). Drill the
house wiring hole by using a 1½” hole saw centered
with the pilot hole previously made in 4.
Assemble the bracket to the side frame using a
Phillips screwdriver and 3 provided no. 8 x 5/8”
wood screws. Repeat for the other side frame.