37
Before
Neutral
terminal
Ground strap
Terminal
block
Ground
plate
(grounding
to range)
Ground
screw
Ground strap
or
Neutral terminal
Terminal
block
After
Bracket
Conduit
Wire tips
Terminal
block
Installation Instructions
ELECTRICAL CONNECTIONS (CONT.)
3-WIRE CONDUIT INSTALLATION6 4-WIRE CONDUIT INSTALLATION7
A
A
B
C
8
B
Proceed to Step 8.
Loosen the 3 lower terminal screws from the termi-
nal block. Insert the center bare wire (white/ neu-
tral) tip through the bottom center terminal block
opening. On certain models, the wire will need to
be inserted through the ground strap opening and
then into the bottom center block opening. Insert
the two side bare wire tips into the lower left and
the lower right terminal block openings. Tighten the
screws until the wire is firmly secure (approximately
20 inch-lbs.).
NOTE: ALUMINUM WIRING:
Aluminum building wire may be used but it must be
rated for the correct amperage and voltage to
make connection. Connect wires according to this
Step 6 or Step 7 depending on number of wires.
Wire used, location and enclosure of splices, etc.,
must conform to good wiring practices and local
codes.
Skip to Step 8 and proceed with the installation.
Loosen the three lower terminal screws from the
terminal block. Remove the ground screw and
ground plate and retain them.
Cut and discard the ground strap.
DO NOT DISCARD ANY SCREWS.
Insert the ground bare wire tip between the range
frame and the ground plate (removed earlier) and
secure it in place with the ground screw (removed
earlier). Insert the bare wire (white/neutral) tip
through the bottom center of the terminal block
opening. Insert the two side bare wire tips into the
lower left and the lower right terminal block open-
ings. Tighten the screws until the wire is firmly secure
(approximately 20 inch-lbs.).
Wire used, location and enclosure of splices, etc.,
must conform to good wiring practices and local
codes.
Replace the wire cover on the range back by slid-
ing its two lower retaining tabs into the slots and re-
placing the screw removed earlier. Make sure that
no wires are pinched between the cover and the
range back.
REPLACE THE WIRE COVER