Loading ...
Loading ...
3
*Important note for 30”/42”/54” Grills:
The main burner and power burner on the
30”/42”/54” grills require the long ori ce.
These ori ces are 1.375” in length. Failure to
use the longer ori ce on these models could
result in a serious  re.
** 41L Long 1.375” in Length
** 53L Long 1.375” in Length
** 50L Long 1.375” in Length
** 57L Long 1.375” in Length
** 35L Long 1.375” in Length
GAS PLUMBING REQUIREMENTS
A pressure regulator must be installed on all gas equipment. All local codes require that a pressure regulator be installed. Removing or failing
to install the pressure regulator can result in  re and serious bodily harm.
An installer supplied gas shut-o valve must be installed in an easily accessible location for all hardplumbed natural gas and liquid propane
applications.
In order for a the grill to perform properly, you must have adequate gas plumbing. Please see the guidelines below to help ensure that you
have the appropriate gas plumbing with respect to gas pipe diameter, length of pipe run and the grills BTU requirements.
IMPORTANT: PLEASE READ AND FOLLOW
Ensure that the gas supplied meets with the minimum pressure requirements. Do
not operate the grill on any gas other than that for which the grill has been set.
Fuel WC Max Inlet WC Min Under
Full Load
Nat Gas 10 in 4 in
LP 14 in 11 in
MODEL-SPECIFIC BTU OUTPUTS
MODEL H BURNER (Btu) ROTISSERIE (Btu) PROSEAR™ / TRIDENT(Btu) TOTAL INPUT
30 W. 1 @ 25,000 Nat / LP 1 @ 14,000 Nat / LP 1 @ 21,000 Nat / LP 62,000 Btu/Hr Nat / LP
36” W. 2 @ 25,000 Nat / LP 1 @ 14,000 Nat / LP 1 @ 21,000 Nat / LP 87,000 Btu/Hr Nat / LP
42” W. 2 @ 25,000 Nat / LP 1 @ 16,000 Nat / LP 1 @ 21,000 Nat / LP 89,000 Btu/Hr Nat / LP
54” W. 3 @ 25,000 Nat / LP 2 @ 14,000 Nat / LP 1 @ 21,000 Nat / LP 126,000 Btu/Hr Nat / LP
MODEL TOP BURNER (Btu) OUTER TOP BURNER (Btu) INNER TOP BURNER (Btu) TOTAL INPUT
Side Burner 1 @ 15,000 Nat / LP N/A N/A 30,000 Btu/Hr Nat / LP
Power Burner N/A 1 @ 34,000 1 @ 13,000 47,000 Btu/Hr Nat / LP
Models NG LP
36”
Main Burner 41 53
ProSear /Trident Burner 44 55
IR Rotisserie 50 57
30” / 54”
Main Burner* 41L** 53L**
ProSear /Trident Burner 42 54
IR Rotisserie 50 57
42”
Main Burner* 41L** 53L**
ProSear /Trident Burner 42 54
IR Rotisserie 48 56
Side
Burner
Top Burner #185 #115
Power
Burner
Outer Burner 50L** 57L**
Inner Burner 35L** 50L**
Internal Pipe Diameter 10 ft. 20 ft. 30 ft. 40 ft.
3/4” 360,000 BTU 245,000 BTU 198,000 BTU 169,000 BTU
Internal Pipe Diameter 50 ft. 60 ft. 70 ft. 80 ft.
3/4” 150,000 BTU 135,000 BTU 123,000 BTU 116,000 BTU