Problem solving guide
88
Problem Cause and remedy
Only open the appliance door when necessary and
for as short a time as possible.
After a while, the temperature will return to normal by
itself.
The appliance door is not properly closed.
Close the appliance door.
After a while, the temperature will return to normal by
itself.
The ambient room temperature is too high. The
higher the ambient temperature, the longer the com-
pressor has to run.
See the information in “Location” in “Installation”.
The wine conditioning unit has not been installed
properly in the building-in niche.
See the information in “Installing the wine condi-
tioning unit” in “Installation”.
The compressor comes
on less and less often
and for shorter periods
of time. The temperat-
ure in the wine condi-
tioning unit rises.
Not a fault. The temperature setting is too high.
Correct the temperature setting.
Check the temperature again after 24hours.
The compressor runs
continuously.
This is not a fault. To save energy, the compressor
runs at a lower speed, but for longer, when less
cooling is required.
An alarm sounds. The appliance door of the wine conditioning unit has
been open for longer than approx. 2minutes.
Close the appliance door.