Ideal 61-765 INDUSTRIES LCD AC/DC TightSight Clamp Meter

Instruction Manual - Page 6

For 61-765. Also, The document are for others Ideal models: 61-763, 61-773, 61-775

PDF File Manual, 36 pages, Read Online | Download pdf file

61-765 photo
Loading ...
Loading ...
Loading ...
6
Test Leads
OPERATION:
High Voltage Warning (HI-V)
The฀meter฀beeps฀and฀lights฀an฀LED฀when฀measuring฀>฀30V฀AC฀on฀the฀VAC฀function฀and฀>30V฀DC
when฀on฀the฀VDC฀function.
Notes:฀This฀feature฀does฀not฀work฀in฀the฀Ohm,฀capacitor,฀continuity฀or฀clamp฀modes.฀Audible฀indica-
tion฀can฀be฀disabled฀by฀pressing฀and฀holding฀the฀Max/min฀button฀while฀turning฀the฀function฀switch
from฀OFF฀to฀any฀desired฀Function.฀Wait฀for฀Hbto฀be฀displayed฀and฀then฀release฀the฀button.฀To
enable, turn the unit off and back on.
Data Hold Feature
Press฀the฀Hold฀button฀on฀the฀side฀of฀the฀meter฀to฀toggle฀in฀and฀out฀of฀the฀data฀hold฀mode.฀“HOLD”
appears in the upper left of the meter display when data hold is active. Use the data hold feature to
lock฀a฀measurement฀reading฀on฀the฀display.฀Press฀the฀Hold฀button฀again฀to฀unlock฀the฀display฀and
obtain฀a฀real-time฀reading.
Peak Feature
In฀PEAK฀mode,฀the฀meter฀displayed฀the฀PEAK฀value฀of฀AC฀Volts฀or฀Current฀measurement.
PEAK฀function฀is฀enabled฀by฀Depressing฀the฀PEAK฀HOLD฀button฀for฀>฀2฀seconds.
To฀Exit฀PEAK฀Mode฀Depress฀the฀PEAK฀HOLD฀button฀again฀for฀>฀2฀seconds.
Max/Min Feature
The฀Max/Min฀records฀the฀maximum฀and฀minimum฀measured฀value.฀Press฀the฀Max/Min฀button฀to
activate฀this฀feature฀and฀to฀toggle฀between฀max,฀and฀Min฀readings.฀The฀unit฀will฀continually฀capture
max฀and฀min฀values฀over฀time.฀Depressing฀the฀max/min฀button฀for฀>2฀sec.฀exits฀the฀mode.฀Note:
To฀record฀max/min฀values฀over฀a฀time฀period฀>30฀min,฀the฀Auto฀Power฀Off฀(APO)฀feature฀must฀be
defeated.
Relative Mode
Press฀”฀button฀to฀enter฀the฀Relative฀mode.฀The฀”฀symbol฀is฀displayed,฀and฀the฀value฀on
the฀display฀is฀subtracted฀and฀stored฀as฀a฀reference฀value.฀In฀the฀Relative฀mode,฀the฀value฀shown
on the display is always the difference between the stored reference value and the present
reading.฀Press฀the฀”฀button฀again฀for฀>฀2฀seconds฀to฀exit฀the฀Relative฀mode.
Zero Feature (61-765, 61-775 models only)
The฀“ZERO”฀button฀is฀used฀to฀zero฀out฀the฀display฀before฀measuring฀DC฀current.฀Press฀the
“ZERO”฀button฀to฀subtract฀out฀the฀non-zero฀number.฀Then,฀measure฀the฀DC฀amps.฀Pressing฀the
“ZERO”฀button฀again฀causes฀the฀“ZERO”฀to฀flash฀and฀the฀original฀offset฀number฀to฀be฀displayed.
Depress฀the฀“ZERO”฀button฀for฀>2฀sec.฀to฀exit฀this฀mode.
5
Note: 61-765 model also measures DC Current.
INCORRECT
Currents
cancel
CORRECT
Single
Conductor
only
Guard ring
CORRECT
Use with
line splitter
Auto Power Off (APO) Feature Disable
The฀meter฀automatically฀powers฀itself฀down฀after฀about฀30฀minutes฀of฀no฀use.฀Press฀any
button, and the meter will wake up and display the last reading taken before power down.
To฀Disable฀APO,฀press฀and฀hold฀the฀(฀฀฀฀฀฀/฀Hz)฀button฀while฀turning฀the฀dial฀to฀any฀desired฀function.
When฀APO฀is฀defeated,฀the฀“APO”฀will฀be฀removed฀from฀the฀display.฀Turning฀the฀meter฀off฀and฀back
on will restore the APO default.
Backlight
Press฀the฀฀฀฀฀฀button฀in฀the฀middle฀of฀the฀meter฀to฀turn฀the฀back-
light฀on฀and฀off.฀The฀green฀backlight฀will฀remain฀lit฀for฀about
3฀minutes฀before฀it฀automatically฀turns฀off฀to฀conserve
battery power.
Note:฀฀Backlight฀consumes฀4x฀the฀battery฀power฀.฀
Measuring AC Current (Amps):
INRUSH
Backlight฀on฀in
all functions.
H
N
CAT IV 600V
CAT III 1000V
CAT II 1000V
Loading ...
Loading ...
Loading ...