Ideal 61-765 INDUSTRIES LCD AC/DC TightSight Clamp Meter

Instruction Manual - Page 3

For 61-765. Also, The document are for others Ideal models: 61-763, 61-773, 61-775

PDF File Manual, 36 pages, Read Online | Download pdf file

61-765 photo
Loading ...
Loading ...
฀3 4
Features
1.฀Tapered฀jaws฀w/hook฀tip
2. Lever
3.฀Function฀Dial
4.฀Main฀Display฀(LCD)
5.฀Volts฀and฀resistance฀(V-Ω)฀฀
input terminal
6.฀Common฀(COM)฀input฀terminal
7.฀TightSight
®
bottom display
8. Protective rubber boot
9.฀Measuring฀Functions
10.฀High฀Voltage฀(Hi-V)฀warning
11.฀Data฀&฀Peak฀Hold
12.฀Max/min
13.฀Relative฀(61-763,฀61-773)
Relative/Zero฀(61-765,฀61-775)
14.฀Backlight
15.฀Capacitance฀(฀฀฀฀฀)฀/฀Frequency฀(Hz)
16.฀฀Tactile฀barrier
Common Features:
1
10
3
15
4
5
9
16
12
13
14
6
8
7
2
Main Display Icons
17.฀9999฀count฀display
18.฀AC฀measurement
19.฀DC฀measurement
20.฀Polarity฀indicator฀for฀DC
21.฀Auto฀Power฀Off฀
(APO)
22.฀Hold
23.฀Min/Max
24. Peak
25. Audible continuity
26. Relative
27.฀Volts/Amps
28.฀Farads
29.฀Hertz/Ohms
30.฀Low฀battery฀indicator
TightSight
®
Display Icons
31.฀9999฀count฀display
32.฀Polarity฀indicator฀for฀DC
33.฀DC฀measurement
34.฀AC฀measurement
35.฀Amps
Main Display
DCAC AMPS
32
31
33 34 35
27
30
26
28
29
25
2223 24
Symbols on the Unit
11
17
18
19
20
21
Risk฀of฀Danger.฀Important฀Information.฀See฀Manual.
Hazardous฀voltage.฀Risk฀of฀electrical฀shock.฀
Application฀around฀and฀removal฀from฀Hazardous฀Live฀conductors฀is฀permitted.
AC฀(Alternating฀Current)
DC฀(Direct฀Current)
Earth Ground
CAT II
Measurement฀Category฀II฀applies฀to฀test฀and฀measuring฀circuits฀connected฀directly฀to฀utilization฀
points฀(socket฀outlets฀and฀similar฀points)฀of฀the฀low-voltage฀installation
CAT III
Measurement฀Category฀III฀applies฀to฀measuring฀circuits฀connected฀to฀the฀distribution฀part฀of฀the฀
building’s฀low-voltage฀installation
CAT IV
Measurement฀Category฀IV฀applies฀to฀test฀and฀measuring฀circuits฀connected฀at฀the฀source฀of฀the฀
building’s฀low-voltage฀installation
~
...
•฀Large฀numbers฀and฀symbols฀displayed
•฀TightSight
®
bottom display
•฀Visual฀and฀selectable฀audible฀indication฀
when voltage is present
•฀Measures฀AC/DC฀Voltage,฀Resistance฀&฀
Capacitance
•฀Audible฀continuity
•฀Bright,฀bold฀backlight
•฀Peak,฀max/min,฀data฀hold
•฀Selectable฀Auto฀power฀off฀and฀low฀battery฀
indicator
•฀Tapered฀jaws฀for฀reaching฀into฀tight฀spaces
•฀Hook฀tip฀for฀easier฀wire฀separation
•฀Protective฀rubber฀boot
•฀Electronic฀overload฀protection฀on฀all฀
ranges
•฀Cat฀IV-600V/Cat฀III-1000V฀
•฀All฀models฀employ฀a฀High฀Frequency฀
Reject฀(HFR)฀circuit฀to฀filter฀noise฀or฀
help in making accurate measurements
on฀complex฀wave฀shapes฀like฀those฀
found฀on฀Adjustable฀Speed฀Drives฀
(ASDs)
Model Specific Features:
•฀61-763:฀฀660AAC฀•฀61-773:฀฀1000A฀AC
•฀61-765:฀฀660A฀AC/DC฀•฀61-775:฀฀1000A฀AC/DC
Loading ...
Loading ...
Loading ...