4. Hanging Bracket Installation.
page 3
ON
OFF
ON
OFF
3. Installation Preparation.
This fan can be mounted as a flushmount
on a regular (no-slope) ceiling only. Downrod
installations are not available for this fan.
Installation requires these tools:
Phillips screwdriver, flat-head screwdriver,
adjustable pliers or wrench, stepladder, wire
cutters, and rated electrical tape.
downrod
installation
flushmount
installation
CANNOT be
installed on
angled or
vaulted ceilings
blade edge
7 feet
(2.13m)
(76cm)
30
inches
10ft. - 12ft.
10ft. - 12ft.
(3.05m - 3.66m)
(3.05m - 3.66m)
To prevent personal injury and damage, ensure
that the hanging location allows the blades a
clearance of 7ft. (2.13m) from the floor and 30in.
(76cm) from any wall or obstruction.
This fan is suitable for room sizes up to
144 square feet (13.4 square meters).
Turn off circuit breakers to current fixture from
breaker panel and be sure operating light switch
is turned to the OFF position.
WARNING: Failure to disconnect power supply
prior to installation may result in serious injury.
Remove existing fixture.
WARNING: When using an existing outlet box, be
sure the outlet box is securely attached to the
building structure and can support the full weight
of the fan. Ensure outlet box is clearly marked
"Suitable for Fan Support." If not, it must be
replaced with an approved outlet box. Failure to do
so can result in serious injury.
CAUTION: Be sure outlet box is grounded properly
and that a ground wire (GREEN or bare) is present.
Remove 4 motor mounting nuts and flat
washers from hanging bracket--save for later use.
["Hanging Bracket Installation" continued on
next page.]
hanging
bracket
motor
mounting
nuts and
flat washers