TROUBLESHOOTING
Problem Possible Cause Corrective Action
White powder residue
forming within burner
box or on adjacent walls
or furniture.
1. When heated, the vapors
from furniture polish, wax,
carpet cleaners, etc., turn
into white powder residue.
1. Turn heater off when using
furniture polish, wax, carpet
cleaner or similar products.
Heater produces un-
wanted odors.
1. Heater is burning vapors from
paint, hair spray, glues, etc.
See IMPORTANT statement,
page 26.
2. Gas leak. See Warning State-
ment at the top of page 26.
3 Low fuel supply.
1. Open a window to ventilate
room. Stop using odor caus-
ing products while heater is
running.
2. Locate and correct all leaks
(see Checking Gas Connec-
tions, page 16).
3. Rell supply tank (Propane/
LP models).
Heater shuts off in use
(ODS operates).
1. Not enough fresh air is avail-
able.
2. Low line pressure.
3. ODS/pilot is partially
clogged.
1. Open window and/or door for
ventilation.
2. Contact local gas supplier.
3. Clean ODS/pilot (see Care
and Maintenance, page 24).
Gas odor exists even
when control knob is in
OFF position.
1. Gas leak. See Warning
Statement at top of page 26.
2. Control valve is defective.
1. Locate and correct all leaks
(see Checking Gas Connec-
tions, page 16).
2. Contact customer service.
Moisture/condensation
noticed on windows.
1. Not enough combustion/
ventilation air.
1. Refer to Air for Combus-
tion and Ventilation require-
ments, page 7.
ACCESSORIES
To purchase these heating accessories please visit our website www.factorybuysdirect.com
or give us a call at 1-855-607-6557.
EQUIPMENT SHUTOFF VALVE
For all models. Equipment shutoff valve with
1/8" NPT tap.
Existing Gas Line
Shutoff Valve
Flexible
Connector
Flare & Pipe
INSTALLATION KIT
Loading ...
Loading ...
Loading ...