CAUTION: Never use a wire,
needle, or similar object to clean
ODS/pilot. This can damage
ODS/ pilot unit.
Use a vacuum cleaner, pressurized air, or a
small, soft bristled brush to clean.
A yellow tip on the pilot ame indicates dust
and dirt in the pilot assembly. There is a small
pilot air inlet hole about 2" from where the
pilot ame comes out of the pilot assembly
(see Figure 33). With the unit off, lightly blow
air through the air inlet hole. You may blow
through a drinking straw if compressed air is
not available.
CABINET
ODS/PILOT
Air Passageways
Use a vacuum cleaner or pressurized air to
clean.
Exterior
Use a soft cloth dampened with a mild soap
and water mixture.
Wipe the cabinet to remove dust.
CARE AND MAINTENANCE
Figure 33 - Pilot Inlet Air Hole
LOGS
If you remove logs for cleaning, refer to Installing Logs, page 17, to properly replace logs.
Replace log(s) if broken or chipped (dime-size or larger).
(Back of pilot
shown for clarity)
Pilot Air
Inlet Hole
Natural Gas
Burner
Propane/LP
Gas Burner
Thermocouple
Pilot Air Inlet Hole
Ignitor
Electrode
SERVICE HINTS
When Gas Pressure Is Too Low
pilot will not stay lit
burners will have delayed ignition
replace will not produce specied heat
propane/LP gas supply might be low (propane/LP units only)
You may feel your gas pressure is too low. If so, contact your local gas supplier.
TECHNICAL SERVICE
You may have further questions about installation, operation, or troubleshooting. If so, contact
Factory Buys Direct at 1-855-607-6557.
When calling, please have your model and serial numbers of your heater ready.