ASSEMBLY FOR PORTABLE COMPRESSORS
Installing Wheels, Handles, Rubber Foot
Strip
THE WI-IEELS AND HANDLE DO NOT PRO-
VIDE ADEQUATE CLEARANCE, STABIL-
ITY OR SUPPORT FOR PULLING THE UNIT 2.
UP AND DOWN STAIRS OR STEPS. THE
UNIT MUST BE LIFTED, OR PUSHED UP A
RAMP.
Attach the handle tothe compressor saddle by insert- 3.
ing the handle inside the compressor saddle and
lining up the two bolt holes on each side. Install the
four screws, two on each side. Tighten securely.
H may be necessary to brace or support one
end of the outfit when attaching the wheels
and the rubber foot strip because the air
compressor will have a tendency to tip.
Install one shoulder bolt and one nut for each wheel
using upper bolt hote for 30 and 33 gallon units.
Tighten securely. The outfitwill sit level ifthe wheels
are propedy installed.
Clean and dry air tank leg opposite wheels. Remove
the protective paper stdp from the adhesive backed
rubber foot strip. Attach the rubber foot strip to the
bottom of leg. Press firmly into place.
,
REMOVAL OF SHIPPING BOARDS AND INSTALLATION
FOR STATIONARY (PERMANENTLY MOUNTED) UNITS
It may be necessary to brace or support one
side of the outfit when removing the ship-
ping boanJs because the air compressor will
have a tendency to tip.
Remove all packaging suchthat onlythe compressor
on the pallet remains. Remove and discard the (4)
screws and washers that hold the compressor to the
pallet.
2_ This compressor isdesigned to be bolted directly to a
level floor. Prior to installing, place the newwashers
which are supplied withthe compressor, between the
feet and floor such that the dng base at the bottom of
the tank does not contact the floor. Tighten bolts 15-
20 tt. tbs.
INSTALLATION AND BREAK-IN PROCEDURES
Location of the Air Compressor
Locate the air compressor in a clean, dry and well
ventilated area. The air filter must be kept clear of
obstructions which could reduce air delivery of the air
compressor, The air compressor should be located at
least 12"away from thewall or other obstructionsthat will
interfere with the flowofair. Theaircompressorheadand
shroud are designed to allow for proper cooling.
Break-In Procedures
The procedure isrequired only once, before the compres-
sor is put into service. Operate the compressor with the
regulator or shut-offvalve fully openfor 15 minutes. Make
sure that no pressure is building in the tank. After 15
mintues, close the regulator or shut-off valve and allow
the tankto fillto cut-out pressure and then the motor will
stop. Your compressor is now ready for use.
Lubrication and Oil
This unit needs no lubrication or oiling.