ELECTRICAL CONNECTIONS
1. The installation of this appliance must conform with all applicable local codes. In the absence of
local codes, the installation must conform to the latest level of the National Electric Code, and
ANSI/NFPA 70.
2. This appliance is configured to work with 208, 220, 240 volt single phase 60Hz power.
3. Unit must be grounded.
4. The electrical connection exits the appliance at the lower rear toward the right (viewed from
front) side. Where a 4” handy box is supplied for field connections.
5. If the electrical supply is not turned on or is interrupted, the appliance will not operate.
6. The applicable wiring diagram for this appliance is affixed to the appliance.
7. The circuit where you plug your appliance must be grounded and polarized.
8. We recommend the circuit for your appliance be a non-GCFI dedicated line.
9. It is recommended that your circuit never include a microwave oven.
10. The electrical connection provided is 4 wires…neutral, ground, L1, L2.
11. If the current power is a 3 wire system it will be required to place a jumper wire from the ground
to neutral location on the terminal block located inside the control compartment of the unit.
SERVICE
If the appliance requires service, to gain access to the control compartment panel please follow the
below steps:
Remove screws attaching control panel.
Let control panel slide down from mounting pins, be careful with wiring connected to control
panel.
Pull control panel forward to remove.
REPLACEMENT PARTS
Replacement Parts can be acquired by calling Customer Service at 1-800-449-8691
WARNING
This appliance is intended to be grounded. Do NOT cut, remove or disregard the grounding
wire in this unit. If the appliance is not grounded severe shock hazards can exist.