WARNING
Improper connection of the equipment earth/ground
conductor can result in a risk of electric shock.
Check with a qualified electrician or service person if
you are in doubt as to whether the dryer is properly
connected to a protective earth/ground.
W886
Do not modify the plug provided with the cord-kit - if it will not
fit the outlet, have a proper outlet installed by a qualified electri-
cian.
The dryer has its own terminal block that must be connected to a
separate branch, 60 Hertz, single phase circuit, AC (alternating
current) circuit, fused at 30 Amperes (the circuit must be fused on
both sides of the line). Electrical service for the dryer should be
of maximum rated voltage (208 or 240 Volt, depending on heat-
ing element) listed on the serial plate. Do not connect dryer to
110, 115, or 120 Volt circuit.
Heating elements are available for field installation in dryers
which are to be connected to electrical service of different volt-
age than that listed on serial plate, such as 208 Volt.
NOTE: Branch circuit wire size requirements to laundry
room outlet are shown in table below.
Wire Length Wire
Less than 15 ft. [4.5 m] Listed No. 10 AWG Copper
wire only
Table 5  continues...
Wire Length Wire
Longer than 15 ft. [4.5 m] Listed No. 8 AWG Copper
wire only
Table 5
The power cord connection between wall receptacle and dryer
terminal block IS NOT supplied with dryer. Type of power cord
and gauge of wire must conform to local codes.
Connecting Power Cord with Three-Wire Plug
NOTE: Four-wire cord is required for new branch-cir-
cuit installations, mobile homes or where codes do not
permit grounding through neutral.
NOTE: The power cord is NOT supplied with the elec-
tric dryer. Type of power cord and gauge of wire must
conform to local codes and instructions. The method
of wiring the dryer is optional and subject to local code
requirements.
NOTE: Connect the dryer to the power supply with the
MAXIMUM RATED VOL
TAGE listed on the serial plate.
NOTE: Use COPPER WIRE only.
Shorter than 15 ft. (4.5 m) – use 10 AWG
Longer than 15 ft. (4.5 m) – use 8 AWG