Speed Queen LDEE7RGS173TW01

User Manual - Page 14

For LDEE7RGS173TW01.

PDF File Manual, 23 pages, Read Online | Download pdf file

LDEE7RGS173TW01 photo
Loading ...
Loading ...
Loading ...
D233I_SVG
2
3
4
1
5
1. New Stainless Steel Flexible Connector – (Use design
CSA certified connector) Use only if allowed by local co-
des
2. 1/8 in. NPT Pipe Plug
3. Equipment Shut-Off Valve
4. Black Iron Pipe:
Shorter than 20 ft. [6.1 m] – Use 3/8 in. [9.5 mm] pipe.
Longer than 20 ft. [6.1 m] – Use 1/2 in. [12.7 mm] pipe.
5. 3/8 in. NPT Gas Connection
Figure 5
4. Tighten all connections securely but don't overtighten to avoid
breaking or bending the gas valve bracket. Turn on gas and
check all pipe connections (internal & external) for gas leaks
with a non-corrosive leak detection fluid.
NOTE: The dryer and its appliance main gas valve must
be disconnected from the gas supply piping system
during any pressure testing of that system at test pres-
sures in excess of 1/2 psi [3.45 kPa]. Refer to Check
Heat Source.
NOTE: DO NOT connect the dryer to L.P. Gas Service
without converting the gas valve. Install L.P. Gas Con-
version Kit 649P3, available at extra cost.
L.P. (Liquefied Petroleum) Gas, 2500 Btu/ft.
3
[93.1 MJ/m
3
], serv-
ice must be supplied at 10 ± 1.5 inch water column pressure.
For proper operation at altitudes above 3000 feet [915 m] the L.P.
gas valve spud orifice size must be reduced to ensure complete
combustion. Refer to Table 4 .
L.P. Altitude Adjustments
Altitude Orifice Size
Part No.feet [m] No. inches [mm]
3000 [915] 55 0.0520 [1.32] 58755
8000 [2440] 56 0.0465 [1.18] D503786
Table 4
Electric Dryer Only - Connect Electrical
Plug
Dryer requires 120/240 Volt or 120/208 Volt, 60 Hertz, 3 or 4
wire electrical supply. Refer to serial plate for specific electrical
requirements.
IMPORTANT: Use only a new U.L. listed No. 10 (copper
wire only) three or four conductor power supply cord
kit rated 240 V
olts (minimum) 30 Amperes and labeled
as suitable for use in a clothes dryer.
NOTE: The wiring diagram is located in the control
hood.
WARNING
To reduce the risk of fire, electric shock, serious in-
jury or death, all wiring and grounding MUST con-
form with the latest edition of the National Electrical
Code, ANSI/NFPA 70, or the Canadian Electrical
Code, CSA C22.1, and such local regulations as
might apply. It is the customer
s responsibility to
have the wiring and fuses installed by a qualified
electrician to make sure adequate electrical power is
available to the dryer.
W521
Earth/Ground Information
This appliance must be properly connected to protective earth/
ground. In the event of malfunction or breakdown, the earth/
ground will reduce the risk of electric shock by providing a path
of least resistance for electric current.
The cord-kit must be equipped with a cord having an equipment-
earth/ground conductor and an earth/ground plug. The plug must
be plugged into an appropriate outlet that is properly installed and
connected to a protective earth/ground in accordance with all lo-
cal codes and ordinances.
Installation
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
14
Part No. D514823R3