Speed Queen LDEE7RGS173TW01

User Manual - Page 10

For LDEE7RGS173TW01.

PDF File Manual, 23 pages, Read Online | Download pdf file

LDEE7RGS173TW01 photo
Loading ...
Loading ...
Loading ...
Area Description
Free Standing/Alcove In-
stallation Closet Installation
A* Dryer sides and rear clearance 0 in. [0 mm] 0 in. [0 mm]
B Dryer top clearance 12 in. [305 mm] 12 in. [305 mm]
C Dryer front clearance Not Applicable 2 in. [51 mm]
D Exhaust duct clearance to com-
bustible material
2 in. [51 mm] 2 in. [51 mm]
E Weather hood to ground clear-
ance
12 in. [305 mm] 12 in. [305 mm]
F Distance from floor or ceiling
to air opening edge
Not Applicable 3 in. [76 mm]
G Area of centered air openings
in closet door. Louvered door
with equivalent air openings is
acceptable. (Minimum clearan-
ces are shown.)
Not Applicable 40 sq. in./open [1016 sq. mm/
open]
H For new installations, it is sug-
gested to locate top of wall vent
42 inches [1067 mm] above
floor to make venting easier to
connect.
42 in. [1067 mm] 42 in. [1067 mm]
* Rear clearance is minimum. 2 inches [51 mm] is recommended for utility connection.
6 inches
[152 mm] is recommended when venting through rear of unit.
Table 1
IMPORTANT: In mobile home installations, gas dryers
MUST be permanently attached to the floor at the time
of installation. Order No. 526P3 Hold Down Kit (availa-
ble at extra cost) for a manufactured (mobile) home in-
stallation. Follow the instructions supplied with the kit.
Installation of unit must conform to the Manufactured Home
Construction and Safety Standards, Title 24 CF4, Part 32-80 or
Standard CAN/CSA-Z240 MH.
Connect Dryer Exhaust System
WARNING
To reduce the risk of fire and combustion gas accu-
mulation the dryer MUST be exhausted to the out-
doors.
W604
WARNING
To reduce the risk of fire and the accumulation of
combustion gases, DO NOT exhaust dryer air into a
window well, gas vent, chimney or enclosed, unven-
tilated area, such as an attic, wall, ceiling, crawl
space under a building or concealed space of a
building.
W045
WARNING
This gas appliance contains or produces a chemical
or chemicals which can cause death or serious ill-
ness and which are known to the State of California
to cause cancer
, birth defects, or other reproductive
harm. To reduce the risk from substances in the fuel
or from fuel combustion, make sure this appliance is
installed, operated, and maintained according to the
instructions in this manual.
W115
Installation
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
10
Part No. D514823R3
Loading ...
Loading ...
Loading ...