3. Connect the other wires to outer terminal block screws. Tighten screws.
!! !!
4. Tighten strain relief screws.
5. Insert tab of terminal block cover into slot of dryer rear panel. Secure cover with hold-
down screw.
6. You have completed your electrical connection. Now go to "Venting Requirements."
3-wire connection: Direct Wire
Use where local codes permit connecting cabinet-ground conductor to neutral wire.
Direct wire cable must have 5 ft (1.52 rn) of extra length so dryer call be moved if needed.
Strip 31/2'' (8.9 cm) of outer covering from end of cable. Strip insulation back 1" (2.5 cm). If
using 3-wire cable with ground wire, cut bare wire even with outer covering. Shape ends of
wires into a hook shape.
_B.9c_
When connecting to the terminalblock, place the hooked end of the wire under the screw of
the terminal block (hook facing right),squeeze hooked end togetherand tightenscrew, as
shown.
1. Loosen or remove center silver-colored terminal block screw.
Place the hooked end of the neutral wire (white or center wire) of direct wire cable under
the center screw of terminal block (hook facing right). Squeeze hooked end together.
Tighten screw.
A. f xtemal ground conductor scre'w
B. Neutral ground wire
C. Ce'nter silver-colore'd tenTlinal block scre'w
O. Neutral wire' (white or cente'r wire)
E. _" (1.9 cm) U[ li_te'd strain relief
Place the hooked ends of the other direct wire cable wires under the outer terminal block
screws (hooks facing right). Squeeze hooked ends togethen Tighten screws.
!! !!
4. Tighten strain relief screw.
5. Insert tab of terminal block cover into slot of dryer rear panel. Secure cover with hold-
down screw.
6. You have completed your electrical connection. Now go to "Venting Requirements."