6
Frequency of cleaning/replacing the lter :
Filter Clean/replace Frequency Filter code
Pre filter Clean Every 2 months
2in1 Active Carbon & Particle filter Replace Every 12 months XD6220F0
Before carrying out any maintenance operation, be sure to unplug the power plug to ensure complete out of
power. You can use a slightly wet cloth to clean the purifier body.
Important: Do not clean it with anything that grinding nature so to avoid damaging to the surface of the
purifier.
When reaches 95% service life of the lter mesh, the corresponding light will ash in a breathing status,
and the buzzer will ring for one minute to remind the user to replace the lter mesh.
* The ashing light indicates that the usage of the lter mesh is about to end.
The corresponding light will ash in a breathing status when there is almost full of dust in the lter mesh,
then you must replace it with new lter mesh. “” The indicator light ashes in a breathing status means
that the lter mesh needs to be replaced.
Performing a force reset:
The filter mesh indicator light on the panel is in breathing statue, the buzzer rings for one minute each
time when the purifier is started, reminding the user to replace the filter mesh. After you replace it, the
corresponding light will be canceled when you press the sleep” key for three seconds and the usage of the
filter mesh will be restarted
If the filter mesh is replaced before its usage, the timing of the filter mesh should be reset by force:
1. After replacing the filter mesh, press and hold the filter mesh reset key for 3 seconds;
2. The corresponding mesh indicator light flashes;
3. Press and hold the rest key for 3 seconds again, the indicator light of the filter mesh goes out and the
buzzer beeps twice, then the purifier will recalculate the usage of the filter mesh.
4. The reset mode will be canceled, if there is no operation for 3 seconds
Caution :
*The working efficiency of the primary filter mesh will be reduced if cannot be cleaned regularly
*Do not use wet primary filter mesh
*Do not wash or reuse too many times of the filter mesh
* Replace the filter mesh in turns, please refer to “Before use” ------” Install the filter mesh”
You can use the following type of filter mesh for replacement:
Please note: certain filters may emit a temporary slight odour, due to the transport and storage conditions.
« TIPS FOR CHANGING FILTERS »
Avoid handling used lters if you suer from allergies or asthma.
Wear gloves when changing the lters, or wash your hands well afterwards.
Put used lters directly into a closed, air-tight bag before throwing them away to avoid
spreading pollutants.
IMPORTANT:
Never use a detergent or metal object to clean the sensors.
The efficiency of the sensors may be reduced if not cleaned regularly.
Cleaning frequency varies depending on the operating environment of the appliance. If it is used in a dusty
environment, clean the sensors more frequently.
STORAGE
When you are not using the appliance, store it in a cool, dry place with ambient conditions no higher than 35°C
70%RH.