13
DUCTLESS RECIRCULATING (AK8000BS ONLY):
Ductless recirculating is intended for applications where an exhaust duct work is not possible to be installed.
When converted, the power pack functions in air “purifying” mode rather than exhausting the air. Fumes and
H[KDXVWIURPFRRNLQJLVGUDZQDQG¿OWHUHGE\DFKDUFRDO¿OWHU7KHDLULVWKHQSXUL¿HGDQGUHFLUFXODWHGEDFN
into the kitchen.
We recommend to always exhaust air outside of the home by employing existing or installing new duct work, if
SRVVLEOH7KHSRZHUSDFNLVPRVWHIIHFWLYHDQGHI¿FLHQWDVDQH[KDXVWXQLW2QO\ZKHQWKHH[KDXVWRSWLRQLV
not possible should you use the power pack in recirculating mode.
:KHQFRQYHUWHGWRUHFLUFXODWLQJPRGHDFKDUFRDO¿OWHULVUHTXLUHGWREHLQVWDOOHGRQWRSRIWKHVWDQGDUG
DOXPLQXPPHVK¿OWHUDQGDUHWXUQDLUYHQWLVQHHGHGWRGLUHFWDLUEDFNLQWRWKHNLWFKHQ7KHVWDQGDUG
DOXPLQXPPHVK¿OWHULVLQWHQGHGWRFDSWXUHUHVLGXHIURPFRRNLQJDQGWKHRSWLRQDOFKDUFRDO¿OWHUKHOSVWR
purify fumes exhausted from cooking in recirculating mode.
Purchase recirculating kit as follows, for AK8000BS ONLY:
Hood Model: Part No. Qty. to Order
AK8000BS ZRC-0100 1
&KDUFRDO¿OWHUVPXVWEHUHSODFHGDSSUR[LPDWHO\HYHU\PRQWKVEDVHGRIIDQDYHUDJHXVDJHRIKRXUDGD\
2UGHUUHSODFHPHQWFKDUFRDO¿OWHUVDVIROORZV
Hood Model: Part No. Qty. to Order
AK8000BS Z0F-C002 1
For detailed installation instructions please refer to manual included with recirculating kit.
,QVWDOOFKDUFRDOILOWHUSODVWLFVLGHXSLQWR
filter bracket. Insert tab cut-out side D of
charcoal filter into bracket first. Lock
charcoal filter into place by pushing down
on side E with locking tabs.
D
E
Maintenance – AK8000BS Recirculating Kit
Loading ...
Loading ...
Loading ...