Now that you have mastered the operating
procedure, here are more features in your
control that you should become familiar
with.
ADDITIONAL THINGS YOU SHOULD KNOW
NOTE
The "Cool" circuit has an automatic 3
minute time delayed start if the unit is
turned o and on quickly. This prevents
overheating of the compressor and possible
circuit breaker tripping. The fan will
continue to run during this time.
There is a 2-Second delay for the
compressor shutting down when selecting
FAN ONLY. This is to cover the possibility
of having to roll through to select another
mode.
The control will maintain the set
temperature within 2 degrees Fahrenheit,
between 60°F and 90°F degrees.
After a power outage, the unit will
memorize the last setting and return the
unit to the same setting once power is
restored.
• The unit should be operated in a
temperature range of indoor side 60°F -
90°F (16°C - 32°C), outdoor side 64°F -
109°F (18°C - 43°C). Performance may be
reduced outside of these operating
temperatures.
14 OPERATING INSTRUCTIONS
Air Directional Louvers
Air directional louvers control air flow
direction. Your air conditioner has the louver
type described below.
Slider Type
The louvers will allow you to direct the air
flow Up or Down and Left or Right
throughout the room as needed. Drag the
adjuster tablet until the desired
Left/Right direction is obtained. Pivot
horizontal louvers until the desired
Up/Down direction is obtained.
(6-WAY)
ADJUSTER TABLET