Performance Data Sheet
SmartWaterFiltrationSystem
GWF/ HWF Cartridge
Thissystemhas been testedaccordingto NSF/ANS142/53forreduction of the substanceslisted below.
Theconcentrationof the indicated substancesin water entering thesystemwas reduced to a concentration
less thanorequal to thepermissible limit for water leaving the system,as specified in NSF/ANS142/53.*
(100%safety factors built in for unmetered usage)
Parameter
( :hlorin(
T & ()
Partk:ulale**
Parameter
USEPA
MCL
Stmldard No. 42: Aesthetic Effects
]nfluent Eftluent
Challenge Concentration Aver age Maximtml
2.0 mgiI. + 10% 0.02 ppm 0.05 ppm
at least 10,000 particles/mE 3,978 7,800
% Reduction
Average Mhfimum
98.90% 97.37!'{
98.00!'_ 96.10%
Stmadard No. 53: Health Effects
hd]uent Eftluent
Min. Required
Reduction
> 50%
>85%
USEPA
MCL
1 NTI **'::
{){).95%Reduction
15 ppl)
15 ppl)
0.0002 lq)m
0.003 ppm
0.100 ppm
99%
ChMlel_e Conceaaration Average Maximum Aver age
'Ihrbidity 11 + 1 NT[ *'::* 0.07 NTI 0.1 NT[ 99.71%
C>,ts Minimum 50,000 L 26 55 99.97!_
Lead aI pII 6.5 0.15 mgiL + 10!:i 1 ppb 1 ppb 99.37%
Lead al pII 8.5 0.15 mgiL + 10{:i 1.8 ppb 4.3 ppb 98.8%
Lindane 0.t,q)2 mgiL + 10{:{ 0.00005 ppm 0.00005 ppm 91.93%
Atl-4zine 0.t,q)9 mgiL + 10{:{ 0.t,q)2 ppm 0.003 ppm 76.1{t%
2,4-I) 0.210 mgiL + 10{:{ 0.042 ppm 0.090 ppm 84.8{t%
zYs/)estos 107 to I(Y tibep_iL; t).32 MFLiml 1.2 MFI.iml 99.95{_
fibel'_ gwater tllan
10 micrometel'_ in length
% Reduction
Mhmnum
99.59!_
99.95%
99.37%
97.13%
91.93!_
64.28!_
67.63!_
99.82%
Min. Required
Reduction
0.5 NT[ 7
> 99.95%
0.010 mg/L
0.010 mgiL
0.0002 mg!L
0.0',)3 mgiL
0.07 mgiI.
99%
* Tested using a flow rate of O.5 gpm; pressure of 60 psig; pH of 7.5 _+O.5; temp. of 20 ° _+2,5°C
** Measurement in Particles/ml. Particles used were 0.5-1 microns
*** NTU=Nephelometric Turbidity units
Operating Specifications
(_apacitv: certified for up to 300 gallons (l 135 1); up to six months tot models without a replacement filter indicator light; up
to one vear for models with a replacement filter indicator light
Pressttre requirement: 40-120 psi (2.8-8.2 bar), non-shock
Temperature: 33-100°F (0.6-38°C)
Flow rate: 0.5 gpm (1.9 lpm)
General InstallationlOperation/Maintenance Requirements
Flush new cartridge at full flow for .3 minutes to Imrge, out trapped air.
Replace cartridge when flow becolnes too slow.
Special Notices
li_stallation ii_sti uctions, parts and service availability, and standard warranty are inchtded with the product when shii)ped.
This driI_king water sx:steln Inust be inaintained according to inanufacturer's instluctions, inchtdii_g replacen/ent of filter
ca rtridges.
Do not use with water that is inicrobiologically tmsali _ or of tu_klmwn quali W without adequate disinfection before or
after the svsteln. Svstelns certified for cyst reductiola inav be used on disinfected water that inav contain filterable cysts.
The contanfilmlatS or other substances relnoved or reduced by this water treatlnelat s_steln are not necessarily in your
water.
Check ti)r compliance with the state and local laws and regulations.
Note that while the testing was performed trader standard laboratory conditions, actual performance may vary. Systems
Inust be installed and operated ill accordance with inanutacturer's reconllnended procedures and guidelines.
System Tested and Certili(d by NSF Int( rnational against ANSI/NSF Standard 42 & 53 t)n-
I1:1(: r((lt/(:tioll of:
Standard No. 42: Aesthetic Effects
Chemical Unit
'Ihst_ and ()dot Reduction
Chlorine Reduction
Mechanical Fihration Lnit
Particular( Reduction, Class I
Standard No. 53: Heahh Effects
Chemical Re(luction/nit
I.ead and Atrazine Reduction
Lindane and 2,4-1) Reduction
Mechanical Fihration Unit
Ttwbi(litv Reduction
Cyst and Asbestos Reduction
Mantd'actured tk)r: (;( neral Electri( (_oml)any, I.ouisville, KY 40225