E TR OUBLESHOOTING
Review this chaff to find do-it-yourself solutions for minor performance problems.
WARNINGBectricol Shock Hazard
Disconnect electrical supply before servicing or cleoning the unit.Failureto do so could resultin
electrical shock or personal injury.
Cleaner won't run.
Poor job of dirt
pick-up.
Cleaner picks up
moveable rugs or
pushes too hard.
Lightwon't work.
Brush assembly does
not turn.
Performance indicator
(optional) isred.
i. Unplugged at wall outlet.
2. Tripped circuit breaker/blown fuse
at household service panel.
3. On/Off switch not turned ON.
4. Tripped thermostat on suction
motor. (Brush and light stillwork).
1. Full or clogged dust bag
2. Wrong pile height setting.
3. Worn brush.
4. Clogged nozzle.
5. Clogged dirt tube.
6. Hole in hose.
7. Broken belt,
8. Hose not inserted fully.
9. Tripped Belt Protection System,
10. Dirty Motor Safety Filter.
1. Wrong pile height setting.
1. Burned out light bulb,
2. Attachment hose not properly
inserted into base at rear.
3. Height Adjustment Lever in Bare
Floor Setting.
4, Tripped Belt Protection System
|,
2.
3.
4.
5.
Broken belt.
Tripped Belt Protection System
Attachment hose not properly
inserted into base at rear.
Height Adjustment Lever in Bare
Floor Setting.
Wrong pile height setting,
1. Full or clogged dust bag
2. Dirty Motor Safety Filter.
3. Clogged airflow passage.
4. Certain attachment tools.
I. Plug infirmly, push On/Off switch to ON.
2. Reset circuit breaker or replace fuse
3. Push On/Off switch to ON.
4. Allow cleaner to cool down for 20-30 minutes.
Check for full bag, clogged filter, nozzle.
i. Change bag, (page 12).
2. Adjust setting, (page 6).
3. Replace brush, (page 20).
4. Clean nozzle area, (page 18),
5. Clean dirt tube, (page 18).
6. Replace hose.
7. Replace belt, (page 15].
8. Insert hose fully, (page 7),
9. Check for clogs, (page 18).
10. Clean filter, (page 14).
1. Adjust setting, (page 6).
i. Change light bulb, (page 19).
2. Check for proper insertion.
3. Switch lever to ex io, medium or high
depending on carpet height
(optional - page 6).
4. Reset Belt Protection System (page 10),
1.
2.
3.
4.
5.
Replace belt, (page 15).
Check for clogs, (page 18).Reset Belt
Protection System, (page 10).
Check for proper insertion.
Switch lever to ex io, medium or high,
(optional - page 6),
Adjust setting, (page 6).
1. Change bag, (page 12).
2. Clean filter, (page 14).
3. Clear clog from airflow passage, (page 18),
4, Thisisnormal. Light should go off when
tool isremoved.
2O