Installation
28
Adjusting the minimum setting for natural
or city gas
1. Light the burner and turn it to the minimum
position.
2. Remove the knobs by pulling them
upwards.
3. Turn the regulating screw on the side of
the valve spindle until a steady minimum
flame is achieved.
4. Refit the knob and verify that the burner
flame is stable.
5. Turn the knob rapidly from the maximum
to the minimum setting: the flame should
not go out. Repeat the operation on all
gas valves
Adjusting the minimum setting for LPG
Tighten the screw located at the side of the
valve spindle clockwise all the way.
Lubricating the gas valves
Over time, the gas valves may become
difficult to turn and become seized. Clean
them internally and replace the lubrication
grease.
Following adjustment to a gas
other than the one originally set in
the factory, replace the gas setting
label fixed to the appliance with
the one corresponding to the new
gas. The label is inserted inside the
injector pack (where present).
Lubrication of the gas valves
should be performed by
authorised persons.