Installation
25
EN
To check the operating pressure of the
appliance it is recommended at least 2
large size burners are used. Ensure
appliance is secured to wall when
installation is completed.
N.G. The regulator must be fitted to the
appliance inlet connection. Gas pressure
must be adjusted to 1.0 kPa when
approximately 50% of the burners are on
high flame, the appliance test point is
located on the regulator.
1 Test Point location
2 Gas inlet pipe
3 Elbow
4 Regulator
U.L.P.G. Gas pressure must be checked to
confirm the appliance operating pressure is
2.75 kPa, the appliance test point is the
Rapid burner injector as shown below.
1. Disconnect the power.
2. Light the auxiliary burner and set to high
flame. Ensure all other burners are off.
3. Zero manometer, then apply flexible
tubing to seal over the Rapid burner
injector, hold securely in place and
check the gas pressure by pressing in the
corresponding burner control knob in,
then turning to high flame position.
4. If the pressure is 2.75 kPa, reassemble
the burner and perform the final checks
as per this instruction manual.
5. If the pressure is not 2.75 kPa,
disconnect the appliance and check/
adjust/replace the LPG cylinder
regulator(s) as appropriate in
accordance with AS/NZS 5601.
Patent 2015101170. For enquires contact
Gas Approval Consulting Pty Ltd Smeg
licence 033 for SAI-400046 only