INSTALLATION INSTRUCTIONS
ELECTRICAL CONNECTIONS (CONT’D)
(6) 3-WIRE CONDUIT INSTALLATION
(A) Loosen the 3 lower terminal screws from the terminal
block. Insert the center bare wire (white/neutral) tip through
the bottom center terminal block opening. On certain models,
the wire will need to be inserted through the ground strap
opening and then into the bottom center block opening.
Insert the two side bare wire tips into the lower left and lower
right terminal block openings. Tighten the screws until the
wire is rmly secure (approximately 20 inch-lbs.).
NOTE: ALUMINUM WIRING
Aluminum building wire may be used, but it must be rated
for the correct amperage and voltage to make connection.
Connect wires according to this Step 6 or Step 7 depending
on the number of wire.
Wire used, location and enclosure of splices, etc., must
conform to good wiring practices and local codes.
(B) Skip to Step 8 and proceed with the installation.
(7) 4-WIRE CONDUIT INSTALLATION
(A) Loosen the three lower terminal screws from the terminal
block. Remove the ground screw and ground plae and
retain them. Cut and discard the ground strap. DO NOT
DISCARD ANY SCREWS.
(B) Insert the ground bare wire tip between the range frame
and ground plate (removed earlier) and secure it in place
with the ground screw (removed earlier) and secure it in
place with the ground screw (removed earlier). Insert the
bare wire (white/neutral) tip through the bottom center of
the terminal block opening. Insert the two side bare wire
tips into the lower left and the lower right terminal block
openings. Tighten the screws until the wire is rmly secure
(approximately 20 inch-lbs.).
Wire used, location and enclosure of splices, etc., must
conform to good wiring practices and local codes.
(C) Proceed to Step 8.
(8) REPLACE THE WIRE COVER
Replace the wire cover on the range back by sliding its
two lower retaining tabs into the slots and replacing the
screw removed earlier. Make sure that no wires are pinched
between the cover and the range back.
Terminal
block
Wire tips
Bracket
Conduit
Before
After
Terminal
block
Cut and discard
the ground strap
Neutral terminal
Ground strap
Terminal
block
Wire tips
Ground
screw
Ground plate
(grounding
to range)
Bracket
21