18
It is not required to remove the control panel or knobs to install
this unit. DO NOT lift the unit from the control panel when
installing.
PREPARE FOR INSTALLATION
Consult a qualified professional installer / licensed contractor.
The in-ground post is designed primarily for installation with a
permanent underground gas supply.
To gain access to the inside of the post, unscrew and carefully open
the access plate on the rear of the post using a medium Phillips-
head screwdriver. Retain the screws.
ROUTE GAS SUPPLY (UNDERGROUND METHOD)
Note: This section addresses an underground gas supply setup.
To connect through the rear of the post, reference the
ROUTE FLEX CONNECTOR section of PATIO-MOUNT
INSTALLATION, and do not perform the steps until after:
attaching the extension post, and installing the post / pouring
the concrete.
1. After running the underground gas supply line to the planned
grill location, dig a hole for the post and extension approximately
18" deep and 10-12" in diameter.
Note: Run the gas supply line up from the bottom of the hole
(a little off center) so that it reaches to approximately 4"
above ground level.
Note: The actual depth of the hole should be such that the shelf
surface is approximately 36.5" above ground level.
2. Verify that the gas supply line fits through the gas line clearance
hole in the bottom of the post (see Fig. 18-
2). The clearance hole is
the larger of the two holes in the bottom of the post and is off center.
3. Verify that the flex connector coming from the inside of the
post will connect properly with the gas supply line.
Fig. 18-1 In-ground install orientation
Ground level
Concrete level
Post
Gas supply
route
4" (approx.)
18"
(approx.)
3-5"
Flex connector
(w/ adapter)
Supply line
Fig. 18-2 Post interior detail
Flex connector
(w/ adapter)
Regulator
Back of timer
valve
IN-GROUND POST INSTALLATION