Owner’s Manual – HydroSensor
DRI-EAZ PRODUCTS, INC.
15180 Josh Wilson Road, Burlington, WA USA 98233
Fax: (360) 757-7950 Phone US: (360) 757-7776 www.dri-eaz.com
The HydroSensor is a moisture probe used to detect moisture in wet carpet and carpet cushion.
Read And Save These Instructions
SAFETY INFORMATION
The nickel plated points on the HydroSensor are extremely
sharp. Take care when collapsing the telescoping tubes, to
avoid the points extending by accident. This could cause injury.
Retract the probe points into the shaft when not in use.
WARRANTY
FILL OUT WARRANTY CARD: Please stop before proceeding
and fill out the warranty card.
INSPECT ON ARRIVAL: When your Dri-Eaz product arrives,
check immediately for signs of shipping damage. If you notice
damage, save the shipping carton for claim purposes, and im-
mediately report the problem to your supplier and the shipping
company. Also, save the carton for shipping in case your prod-
uct ever needs repair at a remote location.
Dri-Eaz promises, to the original purchaser, to perform the
following as needed to correct defects in materials and work-
manship:
1 Year on Parts and Labor: Cover parts and labor costs for the
repair of a Dri-Eaz Airmover, Dehumidifier, Instrument, Acces-
sory, and other product except Marketing Products, for a pe-
riod of one year from the date of purchase.
90 Days on Shipping: Cover shipping costs for the repair of a
Dri-Eaz Airmover, Dehumidifier, Instrument, Accessory, or
other product except Marketing Products, both to and from the
Service Center, for a period of 90 days from the date of pur-
chase.
MODELS COVERED: Instruments: HydroSensor, HydroSen-
sor II, Moisture Counter, Moisture Pro, DHT600, DHT200.
LIMITATIONS: This warranty shall not extend to any products
showing effects of misuse, accident damage, disassembly,
alteration, lack of proper maintenance, corrosive chemicals,
improper voltage, unauthorized repairs, use of other than
genuine parts and materials, fire, flood, normal wear and tear,
or any other causes beyond Dri-Eaz Products' control. The
warranty obligation extends only to the repairs or replacement
of parts found, upon Dri-Eaz Products' examination, to be de-
fective. The foregoing constitutes the entire warranty and no
other warranty, liability, contingency or responsibility, direct,
indirect, consequential or in any way connected with the sale
or operation of products is expressed or implied.
TO RECEIVE WARRANTY SERVICE: You must write or call
for a Return Authorization. You must have the serial number
available. The Dri-Eaz Service Department must authorize all
costs, including shipping, for any Service Centers world-wide.
Please direct questions to an authorized distributor, or to Dri-
Eaz at (360) 757-7776, extension 238.
PRINCIPLE OF OPERATION
The HydroSensor Moisture Probe is designed to detect mois-
ture in carpets, cushion, floors, walls, and furniture. When the
probe tips on the HydroSensor are pushed into materials to
penetrate the surface, an electric current is sent between the
probes. The amount of moisture present in the material deter-
mines how easily the electrical current passes from one probe
to the other.
When moisture is present in a material, the light on the Hy-
droSensor will flash and the transducer will beep. This will oc-
cur at a varying rate (slower or faster flash and beep) depend-
ing on the amount of moisture present.
The 7/8” probe tips are long enough to penetrate shag carpets,
cushion, and flooring materials. With care, the HydroSensor
can also be used to find moisture in furniture, walls, and ceiling
materials.
The HydroSensor will also detect the presence of urine resi-
dues in carpet and cushion. This is because urine salts attract
and hold enough moisture to be detected. A black-light is rec-
ommended to confirm that urine is present.
MODELS
Both Models
1. To expose the sensor points, loosen the black plastic
knob. Push it down and around the “J,” then tighten to lock
in position.
2. Test the unit by placing your fingers across the shaft of the
points and observing the response of the unit.
3. Probe the suspected moisture area with the points.
Flashing and beeping indicates that carpet and/or pad are
wet.
HydroSensor
The HydroSensor has a single, non-telescoping shaft.
HydroSensor II