Maytag MGD6400TQ0 dryer

User Manual - Page 13

For MGD6400TQ0.

PDF File Manual, 80 pages, Download pdf file

Loading ...
Loading ...
Loading ...
CONNECT VENT
1. Using a 4" (10.2 cm) clamp, connect vent to exhaust outlet in dryer. If connecting to
existing vent, make sure the vent is clean. ]-he dryer vent must fit over the dryer exhaust
outlet and inside the exhaust hood. Check that the vent is secured to exhaust hood with a
4" (102 cm) clamp.
2. Move dryer into its final location. Do not crush or kink vent.
3. (On gas models) Check that there are no kinks in the flexible gas line.
4. Once the exhaust vent connection is made, remove the corner posts and cardboard.
LEVEL DRYER
Check the levelness of the dryer by first placing a level on the top of the dryer near the
console.
Then, by placing a level in the crease on the side of the dryer between the top of the dryer and
the dryer cabinet, check the levelness from front to back.
REVERSE DOOR SWING
You can change your door swing from a right-side opening to a left-side opening, if desired.
1. Place a towel or soft cloth on top of the dryer or work space to protect the surface.
Remove the door assembly
1. Open the dryer door.
2. Remove the bottom screw from each of the 2 hinges that attach the dryer door to the front
panel of the dryer.
3. I.oosen the top screw from each of the 2 hinges in Step 2.
,A
B
A
'B
A. Loosen these screws.
B. R@mov_! th@8_! scr(!w8.
Remove the dryer door and the hinges by lifting upward on the door. Lay the door on a
flat, protected surface, with the inside of the door facing up. Remove remaining 2 loose
screws from dryer front panel.
'I
If the dryer is not level, prop up the dryer using a wood block. Use a wrench to adjust the legs
up or down and check again for levelness.
Loading ...
Loading ...
Loading ...