R, Wire Opening Plug
This plug is in the bottom of the EDF cavity. It is
important to keep this plug in position to eliminate
air leakage (Fig. 18)
Fig. 18
S. Motor Cover
1. Remove five screws and lift off (Fig. 19)
Fig. 19
T. Cord
1. Remove strain relief.
2. Disconnect leads and replace cord.
U. Motor
1. Remove bottomplate and agitator (Section A)
2. Remove hood (Section C)
3. Remove trunnion covers and hose clamp
screws. (Section F)
4. Remove motor cover. (Section S)
5. Remove motor sound foam. (late models only)
6. Lift motor out of position and disconnect leads.
The motor is replaced as an assembly. Motor
brushes are available.
V. Motor Brushes
Brushes are supplied as an assembly which
include the brush and brush holder.
To Replace:
1, Pry open tab on brush holder and work out of
holder.
2. Grasp brush holder with needle nose pliers
and pull out of position.
To install:
Position brush holder and slide into position
insuring the terminal connection.
Note: Do not grasp outside of brush holder with
pliers as it could damage the holder and cause
the brush to stick.