RECESSED AREA/CLOSET
INSTALLATION INSTRUCTIONS
Check governing codes and ordinances.
This dryer may be installed in a recessed
area or closet.
The dryer must not be installed where it
will be exposed to water and/or weather.
* Proper operation of dryer cycles
requires temperatures above 45°F (at
lower temperatures, the dryer may not
shut off at the end of automatic cycles
and drying times will be extended).
* Use at least the minimum installation
spacings described below. This will
ensure you have an adequate clearance
for service and proper operation including
flow of combustion and ventilation air,
and that you have a sufficient distance
from combustible construction.
* Be sure your location allows for a
proper exhaust installation. A gas dryer
must be exhausted to the outdoors.
See pages 17-21 for complete exhaust
requirements.
* Check code requirements. Some
codes limit or do not permit installation
of clothes dryers in garages, closets,
mobile homes, or sleeping quarters.
Contact your local building inspector.
NOTE: No fuel-burning appliances may
be installed in the same closet as a dryer.
MINIMUM INSTALLATION SPACING
minimum
ventilation
al'ea
**24 sq. in.
minimum
ventilation
81'ea
F-29"- 't F-*I" ÷11"1<-28'/,0" ''
FrontView SideView
(DoorNotShown) (DoorShown)
FrontView
(DoorWithVent)
* Additionalclearancesforwall, doorandfloor moldingsmayberequired.O"clearance
isacceptablebutnotrecommended.
** Openingisminimumfor closetdoor.Lonvereddoorwith equivalentair
openingsisacceptable.
*** Additionalapaceisneededwhenexternal exhaustelbow isused. CanbeO"clearance
whenhouseexhaustingislinedupdirectlywith dryerexhaust.
J:
3"
f
3"
T
In the above illustration, the installation
spacing is in inches and is the minimum
allowable.
Additional spacing should be considered
for ease of installation and servicing.
If closet door is installed, the minimum
air openings in top and bottom are
required. Louvered doors with equivalent
air openings in top and bottom are
acceptable.
* All installations must be exhausted
outside. Use at least the minimum
dimensions indicated.