Installation
56
Adjusting the minimum setting for natural
or city gas
Light the burner and turn it to the minimum
position. Extract the gas valve knob and turn
the adjustment screw next to the valve stem
(depending on the model) until the correct
minimum flame is achieved.
Refit the knob and verify that the burner
flame is stable. Turn the knob rapidly from
the maximum to the minimum setting: the
flame should not go out. Repeat the
operation on all gas valves.
Adjusting the minimum setting for LPG
Tighten the screw located at the side of the
valve stem clockwise all the way.
Lubricating the gas valves
Over time, the gas valves may become
difficult to turn and become seized. Clean
them internally and replace the lubrication
grease.
Dimensions
Position of gas and electrical connections.
Following adjustment to a gas
other than the one originally set in
the factory, replace the gas setting
label fixed to the appliance with
the one corresponding to the new
gas. The label is inserted inside the
nozzle pack (where present).
Lubrication of the gas valves
should be performed by
authorised persons