InstallationChecklist
Followallinstallationinstructionscoveredinthismanual.
Checkthegassupplypressuretomakesureitiswithintherangeasstatedindatalabel.
Makesurethereisadequateairforcombustionandventilationasdescribedinthismanual.
Maintainproperclearancestocombustiblesandnon‐combustiblesasspecified.
Makesureventingsystemcomplieswithlocalcodes.
Makesuretheremotecontrolcable(ifany)isproperlyfastenedtothewaterheaterterminal.
Makesuretheremotecontrol(ifany)isconnectedinaccordancewithallwiringcodesandregulations
withoutanyexposedconnections.
Contactthelocalgascompanytoensuregassupplypressureiswithinlimits.
DoNOTblockorrestrictanyoutsideairintakeopenings.
Do NOT remove the water heater front cover unless absolutely necessary. This should only be done by
qualifiedpersonnel.
Donotinstallthiswaterheaterwheregroundwatermaycollect.
WaterHeaterLocation
ONLYtobeinstalledOUTDOORS.
Protectedfromfreezingtemperatures.
Properclearancefromcombustiblematerialtobeobserved.
Sufficientfreshairsupplyforproperoperationofwaterheater.
Airsupplyisfreefromcorrosiveelementsandflammablevapours.
Sufficientroomtoservicethewaterheater.
Combustiblematerialsarenottobekeptneartheheaterandvent.
Waterheaterisproperlysecuredtothewall.
WaterSupply
Watersupplyhassufficientpressure.
Airhasbeenpurgedfromwaterheaterandpiping.
Waterconnectionsaretightandleakfree.
Waterfilteriscleanandinplace.
Waterpipesareinsulatedandprotectedfromfreezing.
GasSupply
Gastypematchesthewaterheaterdatalabel.
Gassupplypressureissufficientandwithintherangeasstatedinthewaterheaterdatalabel.
Gaslineequippedwithaservicevalveandsedimenttrapasdes
cribedintheinstallationinstructions.
Approvedpipejointcompoundhasbeenusedonallgaspipeconnections.
Allconnectionsandfittingshavebeencheckedforleakswithsoapywater.
PowerConnection
Supplycordand/orwiringmeetalllocalcodes,andnationalelectricalcodeAS/NZS3000.
Voltagesupplymatchesthelistingindatalabel.
Waterheaterisproperlyearthed.