ISpring T55M 5.5 Gallon Residential Pre-Pressurized Water Storage Tank for Reverse Osmosis (RO) Systems

User Manual - Page 16

For T55M.

PDF File Manual, 29 pages, Read Online | Download pdf file

T55M photo
Loading ...
Loading ...
Loading ...
Page 15www.123filter.com | (678) 261-7611 | Support@123Filter.com
Note: Stages 6 and/or 7 only exist on certain models.
Stage 1 – 3 Pre-Filters
Replace every 6 months or sooner if you notice a decrease in water flow or quality. The
replacement frequency depends on your water usage and source water quality. To protect the RO
membrane from chlorine and other damaging contaminants, it is important to change the pre-filters
according to schedule.
How to change the stage 1 – 3 pre-filters:
1. Shut off the cold water supply valve and tank valve, and open the RO faucet to depressurize
the system. Place a bucket or towel under the system to catch any water spills.
2. If there is enough room under the sink and the filter system is hung on the wall, you can
twist the filter housing off without removing the system from the wall. Otherwise, you will
need to pull the system out, lay it down, and remove the housings at that point. Be careful
with the tubing connections when removing the system.
3. Twist off the filter housings in a counter-clockwise direction using the filter housing wrench.
4. Refer to Installation Step 1.1 to install the new vertical filter cartridges, and tighten the filter
housings back on. Remember not to over tighten them or they will be hard to unscrew next
time.
Stage 4 RO Membrane
Replace every 2-3 years or sooner if the TDS level starts increasing. Check the TDS level at least
once a month to monitor the system’s performance. The TDSrejection rate should be 90%+.To
calculate the rejection rate, divide the RO water TDS into your tap water TDS and subtract from 1.
For example, 20 (RO TDS) / 200 (Tap water TDS) = 0.1 1-0.1 = 0.9 so the TDS rejection rate
would be 90%. (NSF/ANSI STANDARD 58 for RO water filter).