Auxiliary controlsonyourZoneline.
Auxiliary Controls-TerminalConnections
The au_lia_ T controls are located behind
the roon/cabinet below the control panel.
_] Remove the room cabinet. See the
ToRemove the Room Cabinet secdon.
_ Remoxe the screws fl'om the lower panel
fl'ont coxer and lift the panel off.
_]_Mier all desired settings haxe been made,
replace the panel and room cabinet b)
rex'e_ing the above steps.
The owner is responsible fi)r making all
com_ecfions and setting the appropriate
dip switches.
Insert the building hook-up wires into the
bottom ol the temfinal and tighten screw
secm'elv to make the desired connections.
A CAUTION:
Remove screws
and panel to access
terminal connections
hnproper wiring may damage the Zoneline
electronics. No common busing is pemfitted.
Damage or erratic operation may result.
A separate wire pair must be rtm fl'om
each separate controlling switch to each
individual Zoneline.
o
g o
o
Motion Sensor_-J L_ L_ L_
Door Sensor
External Fan
Central Desk Control
[-Common- Ground
White - Heater
-- Yellow - Compressor
Black- Solenoid
Green - High Speed Fan
Green- Low Speed Fan
Red- 24 V AConly
Motion Sensor(Obtainedlocally)
_,_]_en connected, the wall motmted motion
sensor will detect motion in the room and
automatically tm'n the trait ON or OFF.
The door and motion sensms work together
to automaticallv turn the trait ON or OET.
o
Motion Sensor
8