vvvvvv.GEApp/iances.com
Temperature Limiting
Temperature limiting can reduce energ 0' costs
by limiting the lowest temperature that can be
set fl)r cooling and the highest temI)eratm'e that
can be set fin" heating. Temperature limiting is
controlled by switches 1-6 on the second block
of au_lim y controls. Tile fi_t three switches are
used to select the cooling limits, The next three
switches are used to control the heating limits,
This teature is not awfilable with the Remote
Them_ostat-(:lass 2.
aa aa a B@@ aa al
TL1(C)(Temp.Limit1-Cool)
TL2(C)(Temp.Limit2-Cool)
TL3(C)(Temp.Limit%%ol)
oo,,i aal oo ,
TL1(H)(Temp.Limit1-Heat)---_T-"
TL2(H)(Temp.Limit2-Heat)
TL3(H)(Temp.Limit3-Heat)
Temperaturelimiting during COOLmode
(all temperatures shown in °F)
UP DOWN Minimum Maximum
NONE 1,2,3 60° 85°
1 2,3 64° 85°
1,2 3 66° 85°
2 1,3 68° 85°
2,3 1 70° 85°
1,2,3 NONE 72° 85°
1,3 2 74° 85°
3 1,2 76° 85°
Temperature limiting during HEATmode
(all temperatures shown in °F)
UP DOWN Minimum Maximum
NONE 4,5,6 60° 85°
4 5,6 60° 80°
4, 5 6 60° 78°
5 4,6 60° 76°
5,6 4 60° 74°
4,5,6 NONE 60° 72°
4, 6 5 60° 70°
6 4, 5 60° 65°
Heat Boost
_,_]/eil this switch is enabled (UP) and outdoor
teml)eratures are between 25 ° F and 46 ° K heat
pumi) only operation is locked out, This setting is
used to provide sui)plementa_ y heat to the heat
pumi) operation in conditions where tile heat
i)ump only operation is not sufficient to maintain
a consistent, coillfi)i'table i'ooill teillpei'attli'e to
tile constlIlleY,
oqBEaBBBEaBBllaBBaaB aloo%.
BOOST(HeatBoostOperation)
Diagnostics Check-For Technician's Use Only
\_]/en this switch is enal)led (UP), the unit will go
through an ol)erations check of all components,
which takes about 3 minutes (176 seconds).
This diagnostic tool is intended fiw use by
a qualified technidan.
oo%,BBBEaBBBBIlaBEaEaaEaB Ioo%
DIAGNOS(DiagnosticCheck)