Auxiliary ControlsonyourZoneline. _.CEA,,,ia.ces.com
Auxiliary Controls- Dip Switches
The au_lim y dip switch controls are located
behind tile room cabinet, through an opening
below the control panel.
Remove tile room cabinet. See tile ToRemove the
Room Cabinet section.
Tile ti_ctoxy settings will be in tile DOWNposition.
Tile owner is responsible for checking switches
and ensm_ing tile) are in tile desired position.
C:FANCN(Cooling-SmartFan)
H:FANBY(Heating-SmartFan)
CLASS2(RemoteThermostat
LOADSHEDDING(CDC)
FREEZSen(FreezeSentinel)
CONSTFAN(ConstantONFan)
OCCUPIED(OccupancySensor)
m
7 t_
DipSwitches
L DIAGNOS(DiagnosticCheck)
BOOST(HeatBoostOperation)
rL1(H)(Temp.Limit 1-Heat)
TL2(H)(Temp.Limit2-Heat)
TL3(H)(Temp.Limit3-Heat)
TL1(C)(Temp.Limit1-Cool)
TL2(C)(Temp.Limit2-Cool)
TL3(C)(Temp.Limit3-Cool)
All ElectricHeat
X,_hen this switch is enabled (UP), heat pump
operation is locked out, causing tile trait to
proxide only electric resistance heat.
°%°aSmmaEIB_ BalfllflaaBl_ioa_,
L ALLPR(All ElectricHeat)
Cooling-Smart Fan
_]/en this switch is enabled (UP), it allows tile
indoor lira to cycle on/off with tile compresso_:
X4]mn this switch is disabled (DOWN), it allows
the indoor tim to mn continuously.
°a_°B[BI_81_88B8888888B8i °°%°
L C:FANCN(Cooling-SmartFan)
Heating-Smart Fan
When this switch is enabled (UP), it allo_vs tile
indoor tim to run continuousl); When this
switch is disabled (DOWN), it allows tile indoor
tim to cycle on/off with tile heat I)ump or
heater oi)eration.
o ,iaa,aaaiaa ?,
L H: FANCY(Heating-SmartFan)