- 7 -
corners of the char broiler bottom, ensure sufficient space for ventilation;
Adjustable stainless steel legs to make the equipment level, and get the
same level with other series of the same stove; Please lift the equipment
rather than drag if you need to move it;
Open the grate, and take out the support under it, and reinstall grate
after you make sure the thermal radiation plate is unmoved, and dispose the
support;
Supplied gas pressure regulator is factory set at 4”Natural Gas W.C,
and 10”L.P. Gas W.C;
The equipment can only be placed on the nonflammable counter top, and
keep a distance of at least 6 inches(152mm) to equipment’s both sides and
back, and keep a distance of at least 4 inches(102mm) to the bottom;
Do not put anything around the equipment, and on the counter top and bottom,
in order to avoid influencing combustion and air circulation;
Leave enough distance in front of the equipment to take apart the control
panel. All major parts, in addition to the burner remove from the front
intake-tube;
It may be necessary to adjust the balance of air input by authorized and
licensed technicians;
Pipe threading compound must be resistant to the action of liquefied
petroleum gases.
Warning! Use soap water or testing instrument to test whether piping joint
leaks before use, and forbidden to use an open flame to test!
After installing, you should check gas supply pressure. Use a pressure
gauge which is equipped with liquid (such as U-type pressure gauge, the
minimum value is 0.1mbar) or a digital pressure gauge to test. Steps as
following:
●Remove counter top plate, and needle type
pressure joint screw arbor (Fig.1), then
slip rubber tube of pressure gauge over
needle type pressure joint;
●Start the equipment in accordance with the
instructions, measuring gas supply
pressure (dynamic pressure) in the work
state;
●Access to the equipment if measured data
within the limits of table 1, otherwise,
you will need to adjust gas pressure
regulating valve or contact gas supplier
to bargain; Fig.1
●Unplug pressure gauge after you accomplish pressure testing, then
install needle type pressure joint screw arbor.
Important: must screw
joint screw arbor to prevent gas escape!
Loading ...
Loading ...
Loading ...