Read this Performance Data Sheet and
compare the capabilities of this unit with
your actual water treatment needs.
DO NOT use this product where
water is microbiologically unsafe or
of unknown quality without
adequate disinfection before or
after the system. System certified
for cyst reduction may be used on
disinfected water that may contain
filterable cysts.
Use only with cold water supply.
Check for compliance with the
state and local laws and regulations.
The retractable water filtration system
uses a OWF51 replacement cartridge.
Timely replacement of filter cartridge is
essential for performance satisfaction
from this filtration system. Please refer to
the applicable section in this owner’s
manual for general operation,
maintenance requirements and
troubleshooting.
Replacement Elements: OWF51
This system has been tested according to
ANSI/NSF 42 and 53 for reduction of the
substances listed below. The
concentration of the indicated substances
in water entering the system was reduced
to a concentration less than or equal to
the permissible limit for water leaving the
system, as specified in ANSI/NSF 42 and
53.
Tested using a flow rate of 0.75 GPM (2.83 L/min.) and a maximum pressure of 120 psi (827 kPa) under standard
laboratory conditions, however, actual performance may vary. Health Claim Performance tested and certified by NSF
International
*Particle size range classification of test. Particles used were 0.5 –1 microns.
Influent Challenge Effluent Average % Maximum Min. Required Inlet
Substance Concentration Average Reduction Effluent Reduction pH
Lead 0.15 mg/L +/- 10% 0.001 mg/L 99.33% 0.001 mg/L 0.010 mg/L 6.5
Lead 0.15 mg/L +/- 10% 0.002 mg/L 98.66% 0.003 mg/L 0.010 mg/L 8.5
Cyst Minimum 50,000/L 1count/mL 99.99% 3 count/mL > 99.95% NA
Turbidity 11+/-1 NTU 0.12 NTU 98.98% 0.18 NTU 0.5 NTU NA
Lindane 0.002 mg/L +/- 10% 0.00005 mg/L 97.62% 0.00005 mg/L 0.00002 mg/L NA
Atrazine 0.009 mg/L +/- 10% 0.0002 mg/L 97.93% 0.0006 mg/L 0.003 mg/L NA
Chlorine 2.0 mg/L +/- 10% 0.09 mg/L 95.26% 0.17 mg/L *75% NA
Particulate* at least 10,000 900 count/mL 99.68% 2400 count/mL *85% NA
particles/mL
2,4-D 0.210 mg/L +/- 10% 45.45 ug/L 84.42% 100 ug/L 0.0017 mg/L NA
Asbestos
10
7
to 10
8
fibers/L; fibers greater
0.16 MFL/mL 99.96% 0.16 MFL/mL 99% NA
than 10 micometers in length
PERFORMANCE DATA
SYSTEM SPECIFICATION AND PERFORMANCE DATA SHEET
REFRIGERATOR WATER FILTER CARTRIDGE MODEL OWF51
Specifications
Service Flow Rate (maximum) ......................................................0.75 GPM (2.83 L/min)
Rated Service Life OWF50-NI300 (maximum).........................300 gallons/1135 liters
Rated Service Life OWF50-WI500 (maximum)........................500 gallons/1892 liters
Maximum Operating Temperature ...............................................100° F/38° C
Minimum Operating Temperature ................................................33° F/1° C
Minimum Pressure Requirement ..................................................35 psi/138 kPa
Maximum Operating Pressure.......................................................120 psi/827 kPa
1000 Apollo Road
Eagan, Minnesota U.S.A.
EPA EST #35917-MN-1
Standard No. 53: Health Effects
Chemical Reduction Unit
Lead,Atrazine, Lindane and 2, 4-D Reduction
Mechanical Filtration Unit
Cyst,Turbidity and Asbestos Reduction
Tested and certified by NSF International against ANSI/NSF Standards 42 and 53 in models
OWF50-WI500 and OWF50-NI300 for the reduction of:
Standard No. 42:Aesthetic Effects
Taste and Odor Reduction
Chlorine Reduction
Mechanical Filtration Unit
Particulate Reduction Class 1
15