A4-wirepowersupplyconnectionmustbeusedwhentheapplianceisinstalledina
locationwheregroundingthroughtheneutralconductorisprohibited.Grounding
throughtheneutralisprohibitedfor(1)newbranch-circuitinstallations,(2)mobile
homes,(3)recreationalvehicles,and(4)areaswherelocalcodesprohibitgrounding
throughtheneutralconductors.
Ifusing a power supply cord:
Use a UL listed power supply cord kit marked for use with clothes dryers. The kit should
contain:
[] A Ui listed 30-amp power supply cord, rated 120/240 volt minimum. ]he cord should be
type SRD or SRDT and be at least 4 ft (1.22 m) long. ]he wires that connect to the dryer
must end in ring terminals or spade terminals with upturned ends.
[] A UI listed strain relief.
If your outlet looks like this:
4-wirt" rt'cept_cl_' (14-30R)
Then choose a 4-wire power supply cord with ring or spade terminals and U[. listed strain
relief. [he 4-wire power supply cord, at least 4 ft (1.22 m) long, must have four 10-gauge
copper wires and match a 4-wire receptacle of NEMA Type 14-30R. The ground wire (ground
conductor) may be either green or bare. The neutral conductor must be identified by a white
cover.
If your outlet looks like this:
3-wire" re'cept_cle' (lO-30R)
Then choose a 3-wire power supply cord with ring or spade terminals and U[ listed strain
relief. [he 3-wire power supply cord, at least 4 ff (1.22 m) long, must have three 10-gauge
copper wires and match a 3-wire receptacle of NEMA Type 10-30R.
If connecting by direct wire:
Power supply cable must match power supply (4-wire or 3-wire) and be:
[] Flexible armored cable or nonmetallic sheathed copper cable (with ground wire),
protected with flexible metallic conduit. All current-carrying wires must be insulated.
[] 10-gauge solid copper wire (do not use aluminum).
[] At least 5 ft (1.52 m) long.
GROUNDING INSTRUCTIONS
[] For a grounded, cord-connected dryer:
This dryer must be grounded. In the event of malfunction or
breakdown, grounding will reduce the risk of electric shock
by providing a path of least resistance for electric current.
This dryer uses a cord having an equipment-grounding
conductor and a grounding plug. The plug must be plugged
into an appropriate outlet that is properly installed and
grounded in accordance with all local codes and ordinances.
[] For a permanently connected dryer:
This dryer must be connected to a grounded metal,
permanent wiring system, or an equipment-grounding
conductor must be run with the circuit conductors and
connected to the equipment-grounding terminal or lead on
the dryer.
WARNING: Improper connection of the equipment-
grounding conductor can result in a risk of electric shock.
Check with a qualified electrician or service representative
or personnel if you are in doubt as to whether the dryer is
properly grounded. Do not modify the plug on the power
supply cord: if it will not fit the outlet, have a proper outlet
installed by a qualified electrician.
SAVE THESE INSTRUCTIONS