SANITIZING
1. Mix 1.5 fluid ounces (3 tablespoons) of 5.25%
hypochlorite solution (chlorine bleach) with 3
gallons of warm water.
2. Use 1/2 of the solution to sanitize the removed
parts. Soak the parts in the solution. Do not rinse
the parts after sanitizing.
3. Use the remaining solution to sanitize the interior
surfaces of the machine and the bin.
Do not rinse the sanitized areas.
4. Replace all components.
5. Press and hold the
CLEAN
button for
three seconds.
6. When the machine says “Add”, pour 2 teaspoons
of 5.25% hypochlorite solution (chlorine bleach)
into the spray compartment.
7. When the cleaning cycle is complete, the machine
will resume its previous mode
(either OFF or ICE).
8. Immediately rinse off and dry any exterior areas
where sanitizing solution may have spilled.
EXTERIOR CLEANING
Wipe with a damp cloth to remove dust and dirt. Use
a solution of mild dish soap and water if a greasy
residue persists. Wipe dry with a clean,soft cloth.
Never use abrasives, chlorinated or citrus-based
cleaners on exterior panels.
WINTERIZING INSTRUCTIONS
Use the following instructions to prepare your ice
machine for storage or winterization:
1. Descale and sanitize the ice machine per the
instructions in this manual or reference the
cleaning and maintenance videos on our YouTube
channel at True Residential.
2. Turn off the water supply.
3. Disconnect the incoming water line from
the back of the unit.
4. Remove the water filter by twisting it counter
clockwise and pulling it out of the unit. Discard
the water filter.
5. Drain the evaporator compartment by removing
the pump clean-out cap.
6. Pour 1 gallon of propylene glycol (RV antifreeze)
into the bin drain to fill the drain pump.
7. Once the drain pump shuts off and all the
propylene glycol is drained, unplug the unit or
turn off the circuit breaker.
8. Wipe down the interior bin with a dry clean cloth.
9. Re-install the pump clean-out cap.
RESTART INSTRUCTIONS
Use the following instructions to restart your ice
machine after winterization:
10. Install a new water filter in the unit.
11. Reconnect the incoming water line
and turn on the water supply.
12. Plug in the unit.
13. Descale the ice machine per the instructions on
page 39.
14. Press the power button to start ice making.
NOTE: THE FRESH WATER THAT IS INTRODUCED
DURING DESCALING AND START-UP WILL FLUSH THE
PROPYLENE GLYCOL DOWN THE DRAIN.