UBE920 First Degree Fitness Heart Rate Monitor Cardio Equipment

User Manual - Page 25

For UBE920.

PDF File Manual, 27 pages, Read Online | Download pdf file

UBE920 photo
Loading ...
Loading ...
Loading ...
25
Fault
Probable
Cause
Solution
Tank internal surfaces
show green deposit.
Rower is in direct
sunlight or has not
had water treat-
ment.
Add water treatment or change tank wa-
ter as directed in the water treatment sec-
tion of this manual.
Consider using dis-
tilled water to refill tank.
Knocking noise from
inside the control arm
while training, especial-
ly when changing direc-
tions.
Chain requires
tightening or ad-
justment.
Open inspection plate located on front of
control arm and check tension using a
screwdriver or other tool. Use the chain
tensioning bolts located at the rear of the
control arm to tighten or adjust as need-
ed. The chain should have approx 3mm
of slack when properly adjusted. See P.6
for details.
HandGrips slip during
hard training.
PK tank belt re-
quires tightening.
Remove large inspection plate next to the
tank, insert a long tool to push the rear
end cap out from the inside, exposing the
tank belt tensioning bolt. Loosen tank
bolts slightly. Remove upper rubber belt
cover to expose the PK belt. Tighten the
tank tensioning bolt until the belt is too
tight to be twisted from side to side more
than 45 degrees by hand. See P.15 for
details
HandGrip is loose
(either left or right) and
cannot be retightened.
Crank arm threads
are stripped.
Contact service center for replacement.
Then check weekly as recommended.
Computer screen illumi-
nates, but does not reg-
ister when rowing.
Loose or failed
connection. Sensor
gap too wide (see
erratic computer
display).
Check that the computer lead is connect-
ed properly. If connected properly, check
sensor gap. Open main inspection cover
and check behind magnetic ring. Sensor
head to ring gap should be no more than
2.5mm.
The E920 computer
does not illuminate af-
ter battery installation.
Batteries installed
incorrectly or need
replacing.
Reinstall batteries in correct position and
try again. If the LCD screen fails to illumi-
nate, try rotating the batteries slightly in
the computer. If this fails, contact your
local service center.
The E920 computer
display is erratic/slow
while displaying RPM
and WATTS
Gap between sen-
sor and magnetic
ring is too wide.
Once inspection plate is removed, check
behind magnetic ring and inspect sensor
head/ring distance. Gap should be
2.5mm wide or less. Check Magnetic
ring for wobble.
Troubleshooting
Loading ...
Loading ...