PREPARATION CUT COUNTERTOP OPENING
CHANGING BLOWER DISCHARGE (Optional)
The blower is shipped with its discharge facing DOWN. Follow
these steps ONLY if:
the position of the blower discharge needs to be moved so duct-
work does not interfere with floor joists, plumbing or wiring below.
it is necessary to rotate the blower discharge to the RIG HT or LEFT.
Place the unit on its back on a table or work surface.
1,
2.
Lay out and cut the cooktop cut-out far enough FORWARD
so downdraft will fit behind it.
Set cooktop in place and slide it as far forward as possible.
Center and square it with edges of countertop.
DOWN DISCHARGE - MOVING BLOWER LEFT OR RIGHT
CLAMP
CHANNEL_
NUTS
BLOWER
SHEET
METAL_-
SCREW
1. Loosen the 4 nuts and 2 clamp channels.
BOTTOM
FLANGE
2. Slide blower to desired position.
3. Use supplied cover plate to close open space (if any).
4. Tighten wing nuts to secure top of blower and use sheet metal
screws through bottom flange to secure bottom of blower.
LEFT OR RIGHT DISCHARGE
NUT
CLAMP I_-__
CHANNEL L_
,BLOWER
MOTOR
PLUG
SHEET
SCREW
COVERPLATE
1. Remove the 4 nuts and 2 clamp channels.
2. Carefully lift blower and disconnect motor plug if necessary.
Reposition blower and RECONNECT MOTOR PLUG.
3. Use supplied cover plate to close open space (if any).
4. Replace clamp channels and use nuts to secure the blower
in its new position.
5. Use sheet metal screws through bottom flange to secure bot-
tom of blower.
3,
4,
5.
Place the plastic template against the back flange ofthe cook-
top and center it.Trace around template to mark the downdraft
opening.
Remove cooktop from countertop.
Cut downdraft opening. Be careful not to chip edges of coun-
tertop.
MOUNT THE U NIT
LEVELING BRACKET-
FLANGE FACING OUT
\
\
MOUNTING SCREWS
LEVELING BRACKET -
FLANGE FACING IN
\,
2,
Set downdraft into opening. Extend leveling brackets to floor
of cabinet so downdraft sits straight. (Note: Leveling brackets
can be removed and re-attached in other positions. Bottom
flange may have to face inward in tight cabinet installations.)
Secure the downdraft to the countertop as follows: Hold the
downdraft against the back ofcountertop cut-out and tightening
the 2 mounting screws (one on each end of unit) on underside
of countertop. Use a wood shim between screw and underside
of granite countertops.
Screw leveling brackets to bottom of cabinet. Tighten screws
holding leveling bracket to unit on each side.