OPERATION
After you have chosen the desired operation
mode for your stove, press the ON/OFF button
to start the stove ignite cycle.
25
START-UP
When the stove turns on, the ignition indicator
and the combustion blower indicator will appear
on the screen (#7 & 8 in Figure 19) "Ignite" will
also appear in the work stage box on the screen.
After approximately four seconds, the vacuum
switch indicator will appear. Also note that the
hopper lid open indicator "L" will appear anytime
the hopper lid is properly shut and sealed.
The auger indicator will flash on the screen,
indicating that the auger is feeding pellets. Within
5-8 minutes, a fire should ignite. Once the fire is
lit, and the stove achieves operating
temperature, the work stage box on the screen
will read "Heating", and the room blower fan will
engage.
WORKING IN THE DIFFERENT
OPERATION MODES
MANUAL MODE
The manual mode is the default mode setting if
no other mode is chosen before the stove is
turned on. In the manual mode, you have the
ability to change the heat levels, which will
increase or decrease the amount of heat that the
stove puts out.
To change the power level in manual mode, use
the "Scroll Up" or "Scroll Down" buttons on the
control pad. (See #'s 8 and 10 on Figure 17).
Pressing either of these buttons once will move
the power level up or down one level.
NOTE: This mode does not allow you to directly
adjust specific temperatures. The manual mode
simply allows you to dictate the level of heat the
stove is outputting.
TEMPERATURE CONTROL MODE
The Thermostat Mode allows you to set the
temperature of the room. The stove will increase or
decrease the level of heat it outputs automatically
to keep the room at the set temperature. To
increase or decrease the "Call to" temperature, use
the "Scroll Up" or "Scroll Down" button. The current
room temperature will be displayed in the
temperature display box on the screen, as will the
"Call to" temperature.
If the room temperature falls below the "call to"
temperature, the stove's heat power level indicator
will automatically rise to five. When the temperature
has been reached, and maintained for about a
minute, the heat power level will return to one and it
will stay there until more heat is needed.
NOTE: In thermostat mode, the stove will not shut
off or go into standby. It will simply idle and continue
to produce a fire until the room temperature falls
below the "call to" temperature. When idling, the
heat power level will read at level one in the power
level box on the display screen.
WEEKLY MODE
The Weekly Mode allows a user to control and
schedule the stove operation during set times and
days throughout the week. You can select four
different operation times for each of the seven days
of the week.
IMPORTANT: Remember to set your weekly
schedule in Weekly Mode before igniting a fire. If
you attempt to set a weekly schedule while the
stove is running in Manual or Temp modes, the
weekly schedule will not set, and the screen will
prompt you to wait until you have turned the stove
off and it has cooled down before allowing you to
retry.