Read theseinstructionscompletely and carefully.
AdvancePlanning
The wamfing drawer may be installed direct.Iv
into a wall or wall oven cabinem':
The wamling drawer may be installed below
a cotmtertop, a single or double oven and
side bv side using 2 (h'awex_.
_]mn installing wamling drawer with a
cooktop alh_w a 2" minimum fi'om bottom
of a cooktop bm'ner box to top of cutout.
Electrical power cord is located on the right
side of the wamling drawer i,ocate the outlet
within reach of the 56" hmg power cord in
ac!iacent cabinet, within 42" of the right side
or 16" fl'om the left side of the cutout.
A recessed receptacle can be installed on
tile right side of the cutout, 7" IllaXillltllll
fl'om the back of the cabinet.
GroundingtheAppliance
IMPORTANT--(Please readcarefully)
FORPERSONALSAFETY,THISAPPLIANCE
MUST BE PROPERLYGROUNDED.
Do not use an extension cord or adapter plug
with this appliance. Follow National Electrical
codes _lll(l ordinances.
This wamling drawer must be supl)lied with 120V,
60Hz, and connected to an individual, properly
grounded branch circuit, and protected by a 15
or 20 amp circuit breaker or time delay fllse.
A properly grounded 3-prong receptacle
should be located within reach of the drawer's
56" long power cord.
I,ocate the receptacle in an a(!iacent cabinet.
--within 42" of the right side o_;
--within 16" _ff the left side or
__ recessed receptacle may be located on the
right side of the cutout, 7" maMmum fl'om
the back of the cabinet. In this location, the
excess power cord should be coiled and
taped to the right side of the trait,
Recessed receptacle
7" [eax. from rear
_ _ _ _ onrightside
Drill17/"I_eiefor
powercordforleft
orrightsideoutlet
location
IMPORTANT_Please read carefully)
The power cord of this appliance is equipped
with a 3-prong (grounding) plug that mates with
a standard 3-prong grounding wall receptacle to
minimize the possibility of electric shock. The
customer should have the wall receptacle and
circuit checked bv, a qualNed electrician to make
sure tile receptacle is properly grounded and has
the correct I)olari_:
Where a standard 2-prong wall receptacle is
encotmtered, it is the personal responsibili F
and obligation of the customer to have it
tel)laced with a properly grounded 3-prong
wall receptacle.
Do not, under any circumstances, cut or remove
the third (ground) prong from the power cord.
DO NOT USEAN EXTENSION CORD.