Flammable Vapors
FIRE AND EXPLOSION HAZARD
Can result in serious injury or death
_Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
Storage of or use of gasoline or other
flammable vapors or liquids in the vicinity
of this or any other appliance can result in
serious injury or death.
Read and follow water heater warnings and
instructions.
Location Requirements
Carbon Monoxide Poisoning Hazard
Do not install in a mobile home.
Doing so can result in death or
carbon monoxide poisoning.
The Flame Lock®Safety System is designed to reduce the
risk of flammable vapor-related fires. The patented system
protects your family by trapping the burning vapors within
the water heater combustion chamber through the special
flame-trap. The burning vapors literally "burn themselves
out" without escaping back into the room. In the event of a
flammable vapor incident, the Flame Lock ®Safety System
disables the water heater by shutting off the gas supply to
the water heater's burner and pilot, preventing re-ignition of
any remaining flammable vapors in the area. This will not
prevent a possible fire/explosion if the igniter is depressed
and flammable vapors have accumulated in the combustion
chamber with the pilot light off. If you suspect a flammable
vapor incident has occurred, do not use this appliance. Do
not attempt to light this appliance, or depress the igniter
button if you suspect flammable vapors have accumulated
inside or outside the appliance. Immediately call a qualified
person to inspect the appliance. Water heaters subjected
to a flammable vapors incident will show a discoloration on
the flame-trap and require replacement of the entire water
4
heater. Note: Not following these instructions and/or an
inadequate air supply can cause the Flame Lock®Safety
System to disable the water heater. Please make required
installation and venting/air supply changes prior to resetting
the system (see "Combustion Air Supply and Ventilation"
section). IMPORTANT: This water heater has a resettable
thermal switch installed as part of the Flame Lock®Safety
System. Do not attempt to disable or modify this feature in
any way.
Do not use or store flammable products such as gasoline,
solvents, or adhesives in the same room or area near the
water heater. If such flammables must be used, all gas
burning appliances in the vicinity must be shut off and their
pilot lights extinguished. Open the doors and windows for
ventilation while flammable substances are in use.
If flammable liquids or vapors have spilled or leaked in the
area of the water heater, leave the area immediately and
call the fire department from a neighbor's home. Do not
attempt to clean the spill until all ignition sources have been
extinguished.
Keep combustibles such as boxes, magazines, clothes,
etc. away from the water heater area.
Site Location
Select a location near the center of the water piping
system. The water heater must be installed indoors and
in a vertical position on a level surface. Do not install in
bathrooms, bedrooms, or any occupied room normally
kept closed.
Locate the water heater as close to the chimney or gas
vent as practical. Consider the vent system piping and
combustion air supply requirements when selecting the
water heater location. The venting system must be able
to run from the water heater to termination with minimal
length and elbows.
Locate the water heater near the existing gas piping.
If installing a new gas line, locate the water heater to
minimize the pipe length and elbows.
NOTE: This water heater must be installed according to all
local and state codes or, in the absence of local and state
codes, the "National Fuel Gas Code", ANSI Z223.1 (NFPA
54)-current edition.