11
Performance Data - EZ Series DR (DR.PTAC)
Performance Data for EZDR Series
MODELS
EZ07 EZ09 EZ12 EZ15
VOLTS
230 208 277 230 208 277 230 208 277 230 208 277
BTUH COOL
7,200 6,800 7,000 9,500 9,300 9,200 12,000 11,800 12,000 14,500 14,300 15,000
AMPS COOL
2.63 2.74 2.09 3.63 3.82 2.89 4.98 5.31 4.08 6.17 6.73 5.36
WATTS COOL
605 570 580 835 795 800 1,145 1,105 1,130 1,420 1,400 1,485
EER
11.9 11.9 12.1 11.4 11.7 11.5 10.5 10.7 10.6 10.2 10.2 10.1
CFM HIGH COOL
375 340 360 375 340 360 375 340 360 360 360 360
CFM LOW COOL/HEAT
260 240 260 260 240 260 260 240 260 260 240 260
BTUH HEATING
6,400 6,100 6,100 8,500 8,300 8,500 11,000 10,800 11,400 13,600 13,200 14,000
WATTS HEATING
560 535 520 710 685 710 950 900 1000 1180 1155 1300
C.O.P.
3.35 3.34 3.44 3.51 3.55 3.51 3.39 3.51 3.34 3.38 3.35 3.16
NOISE INDOOR/OUT-
DOOR (DBA)
45/69 45/69 45/69 45/69 45/69 45/69 45/69 45/69 45/69 45/69 45/69 45/69
SHIPPING WEIGHT (LB)
132 132 132 132 132 132 132 132 132 132 132 132
Heating options
(1)Voltage is Single Phase, Alternating Current and R.M.S. (2) Heating Capacity (B.T.U./Hr.) based on indoor blower motor and heating elements. (3) Amp values are a combination of indoor
blower motor and heating elements. (4) Minimum Circuit Ampacity ratings conform to the National Electric Code; however local codes should apply
Electrical
EZDR
LINE VOLTAGE 208/230208/230208/230277277
MAXIMUM AMPERAGE1216241624
WALL SOCKET CONFIGURATION
RECEPTACLE NUMBERNEMA 6-15RNEMA 6-20RNEMA 6-30RNEMA 7-20RNEMA 7-30R
ELECTRICAL HEAT OPTIONS 2.53.64.2 - 5.02.5 - 4.25.0
Dehumidifier
Capabilities
Outdoor
% RH
Outdoor
Temp (F)
H2O
Removal
(L/Day)
60
80
7.9
60
90
7.8
62
84
9.6
70
81
11.18
85
90
14.4
82
82
17.02
Heating Option Voltage (I) Wattage BTU/h Amps (2)
3
208 2,780 9,500 13.37
230 3,400 11,600 14.78
277 3,600 12,300 13.00
4
208 4,090 13,900 19.66
230 5,000 17,100 21.74
277 5,000 17,100 18.05
B
208 1,635 5,600 7.87
230 2,000 6,800 8.70
277 2,500 8,500 9.03