5
ENGLISH
[Connection to the water supply]
* The connections to the mains water supply must be made in accordance with the Plumbing Code of Australia and in
accordancewithAS/NZS3500.1andAS/NZS3500.2.Thedualcheckvalve(backow prevention)suppliedwiththisunit
must be connected between the main supply outlet and water inlet of icemaker.
6. ELECTRICAL CONNECTIONS
WARNING
THIS APPLIANCE MUST BE EARTHED
To prevent possible severe electrical shock to individuals or extensive damage to the unit, the icemaker must be connected
viatheexiblesupplycordsuppliedwiththeicemakertoanappropriateoutletsocketinstalledinaccordancewithlocalcodes
and regulations i.e. AS / NZS 3000.
Disconnect the main power supply before any maintenance, repairs or cleaning is undertaken.
* It is recommended that these appliances are connected to a separate 240VAC supply, protected by an appropriate circuit
breaker and Residual Current Device. Check the nameplate on the icemaker for the supply requirements.
*Themaincontrolboxfuseisratedat5Aandshouldonlybereplacedbyaqualiedserviceengineer.
* The service of a licensed electrician may be required to ensure the installation is in accordance with the local codes and
regulations.
* If the supply cord is damaged, it must be replaced by a replacement cord available from Hoshizaki Parts/Service Centres.
[IM-240NE]
* In accordance with the requirement of the IEC standard, the maximum permissible system impedance (Zmax) at the interface
point of the power supply to be connected with this icemaker must be 0.23+j0.23 ohm. Determine in consultation with the
supply authority, if necessary, that the icemaker is connected only to a supply of 0.23+j0.23 ohm or less.
* The wires in the mains lead are coloured in accordance with the following code:
Green & Yellow = Earth
Blue = Neutral
Brown = Live
7. WATER SUPPLY AND DRAIN CONNECTIONS
WARNING
Connect to potable cold water supply only.
* The service of a licensed plumber may be required to ensure the installation is in accordance with the local codes and
regulations.
IM-100CNE
Drain Outlet Rc3/4
Outlet Hose
3/4-3/4 Nipple
Potable Water
Inlet G3/4
Braided SS
Inlet Hose
Drain Outlet R3/4
Outlet Hose
Dual Check Valve