Electrical Connections
Motor Specifications
The AC motor used in this saw is a capacitor-
start, non-reversible type having the following
specifications:
Rated H.P .......................... 1.5
Maximum Developed H.P ............. 2.5
Voltage ........................... 120
Amperes .......................... 11
Hertz (cycles) ....................... 60
Phase ........................... Single
RPM ............................. 3450
Rotation of Arbor Shaft ......... Clockwise
Power Supply
,_ WARNING: Your saw is wired at
the factory for 120V operation. Connect
to a 120V, 15-AMP, branch circuit and
use a 15-AMP, time delay fuse or circuit
breaker. Failure to connect in this way
can result in injury from shock or fire.
A _
_l& WARNING: To avoid shock or fire, if
power cord is worn, cut, or damaged in
any way have it replaced immediately.
Your unit is wired for 120V, it has a plug that
looks like the one shown below. O:igure 107)
@
3-Prong Plug
Grounding Prong
_- Properly
Grounded
Outlet
Fig. 107- Plug forLess Than 150V
Your saw must be properly grounded. Not all
outlets are properly grounded. If you are not
sure that your outlet is properly grounded,
have it checked by a qualified electrician.
WARNING: If not properly
grounded this power tool can cause
electrical shock, particularly when used
in damp locations.
_I&WARNING: If an electrical shock oc-
curs, your reaction to the shock may
bring your hands into contact with the
blade.
This power tool is equipped with a 3-
conductor cord and grounding type plug listed
by Underwriters' Laboratories. The ground
conductor has a green jacket and is attached
to the tool housing at one end and to the
ground prong in the attachment plug at the
other end.
This plug requires a mating 3-conductor
grounded type outlet as shown above. If you
have an outlet that is of the two prong type, it
is recommended that you have a qualified
electrician replace the it with a properly
grounded three prong outlet.