CARE OF YOUR FILTER
'1
DOING .................
A MINERAL,.. NEUTRALIZER FILTER
II
6. Remove the o-rings (3) and top distributor from
the top of the tank,
7. To make room for the new mineral, use a hose to
siphon water from the tank,
8. Using a large neck funnel, add new mineral into
the tank.
DO NOT ADD MINERAL INTO THE BOTTOM
DISTRIBUTOR. Temporarily plug the distributor
tube to prevent accidental mineral spills into it,
DO NOT OVERFILL the tank. Freeboard area (s_
FiG. 6) is needed for proper backwashing, If you
have mineral remaining, you can use it the next
time you refill the tank.
9, Use water to flush the tank top opening Then,
replace the top distributor and 3 o-rings. Be sure
to locate o-ring seals correctly.., FIG. 7.
10. Carefully, install the valve assembly and retain-
ing clamps. DOUBLE-CHECK TO BE SURE
CLAMPS AND RETAINERS ARE SECURELY
FASTENED iN PLACE.
11. Referring to your installation manuat, reconnect
thefiltertothe plumbing, BESURETHE PLUMB-
iNG IS HELD FIRMLY IN PLACE, IN THE VALVE
iNLET AND OUTLET,
12. Place the valve drain hose at the drain point and
secure in place,
13. Return the plumbing bypass valve(s) to SERV-
ICE position.
14. Plug the transformer into the wall outlet. The
filter will complete the backwash cycle, started in
step 1, and will automatically return to service,