Majestic KHLDVP600NTSC Heater

User Manual - Page 28

For KHLDVP600NTSC.

PDF File Manual, 68 pages, Read Online | Download pdf file

KHLDVP600NTSC photo
Loading ...
Loading ...
Loading ...
28
20306742
KHLDV Series Gas Fireplace
Continued on next page
APPROVED LEAK TESTING METHOD
You may check for gas leaks with the following methods only:
Soap and water solution
An approved leak testing spray
Electronic sniffer
NOTE: Remove any excessive pipe
compound from the connections.
Excessive pipe compound can set off
electronic sniffers.
1. Depress and turn knob counterclockwise
to pilot position.
2. Depress fully and hold pilot gas knob. Depress
piezo igniter as many times as needed to ignite pilot.
Keep knob fully depressed for a few seconds.
Release and check that pilot continues to burn.
If the pilot does not stay lit, repeat steps 1 and 2.
LIGHTING PILOT
Pilot Position
Check for gas leaks in each of the following locations:
Pipe from the gas supply line connection to the gas valve
Burner connections Field made joints / gas shutoff valve
Pilot Factory made joints
Each joint or connection All joints on valve and control body
LIGHTING PILOT FOR THE FIRST TIME
MILLIVOLT: OPERATING INSTRUCTIONS
PILO
T
O
F
F
P
I
L
O
T
O
N
WARNING
If using a soap and water
solution to test for leaks,
DO NOT spray solution onto
control body.
WARNING
DANGER
Never check for gas leak with
open ame!
The control has an interlock device that does not allow the lighting of the replace
up to the moment the safety device of the ame has not interrupted the gas ow.
After that period of time (when the magnet is closed), it is possible to start the
lighting operation.
The gas control knob is designed to be operated by hand. DO NOT use any tools
during this operation. Damaged knobs may result in serious injury.
Loading ...
Loading ...
Loading ...